The AirTAC Airtac GAFC Air Service Unit GAFC500C20LN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC500C20LN is a two-piece F.R.L. combination built for a 3/4" line. The first body houses the filter and regulator together, so air is cleaned and set to pressure in one step; the lubricator then adds a metered oil mist downstream. With a lower-pressure regulator, the working range is 0.15-0.4 MPa (20-58 psi), and the metal bowls hold 108 cc for condensate and 225 cc for oil.
The 1910 g assembly uses quick clamps on a T-shape bracket, and the metal bowl is specified by the C code. No gauge is supplied with this model, so the 1/4" gauge connection is available if you need to read the set pressure. The 40 um element handles standard shop air, and the unit is rated for -5 to 70 C with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure.
| Model | Airtac GAFC Air Service Unit GAFC500C20LN |
|---|---|
| Series | GAFC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1910 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC500 is 1/4" if you add one.
| GAFC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR500-20 filter & regulator, GAL500-20 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAFC400 |
| One size up | GAFC600 (curve to 12000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 3/4" line on a CNC lathe or milling machine, where the lower 0.4 MPa ceiling suits light clamping circuits and the lubricator keeps way slides and spindle bearings oiled.
Prepare air for a multi-station assembly bench with pneumatic screwdrivers and pick-and-place units, using the 108 cc drain bowl to handle condensate from a wet compressor line.
Set a stable 0.3 MPa supply for a carton erector or case packer, where the lower pressure range prevents over-force on delicate film seals and the oil mist protects cycling cylinders.
Choose the GAFC500 when a 3/4" port and 1910 g mass suit a fixed machine installation rather than portable tooling. The L type tops out at 0.4 MPa, so confirm your actuators never need more than that; if they do, step to the standard 0.15-0.9 MPa S type. The metal bowl is a build choice, and the catalogue gives no impact or chemical data, so verify it suits your surroundings. The semi-auto drain dumps condensate when pressure drops, with a manual drain for on-demand use, and the 40 um element is the standard grade. The PT thread carries a gauge scale in MPa/psi, though no gauge is fitted here. For spares, order the GAFR500-20 filter-regulator and GAL500-20 lubricator separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of this unit's regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR500-20 filter-regulator on that branch instead of the full combination.
This lower-pressure F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. The temperature range is -5 to 70 C, and the 108 cc drain bowl and 225 cc oil bowl are both metal. Use ISO VG 32 oil in the lubricator, and the complete unit weighs 1910 g.
The N after the port code means no gauge is supplied. The GAFC500 has a 1/4" gauge connection, so you can add a circular gauge later if operators need to read the set pressure. Until then, the lower-pressure regulator is adjusted without a visual reference, so use a test gauge or a calibrated adjuster during setup.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.