The AirTAC Airtac GAR Air Regulator GAR20006LJNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/8" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR20006LJNK is an air pressure regulator that takes a higher supply pressure and holds a steady, lower downstream pressure you set with its knob. It does not filter, clean, or dry the air, and has no drain bowl or filter element. This unit is the lower-pressure (L) type, regulating from 0.05-0.4 MPa (7-58 psi), and weighs 170 g with a 1/8" port.
Its pressed-in self-locking knob prevents the set pressure from drifting due to vibration or accidental knocks, keeping your process stable. The balanced adjustment mechanism holds the setpoint as supply pressure varies. This model ships with no gauge and no mounting bracket, and includes a reverse-flow (reflux) valve attached.
| Model | Airtac GAR Air Regulator GAR20006LJNK |
|---|---|
| Series | GAR200 air regulator |
| Port size | 1/8" (PT thread) |
| Regulation type | Lower pressure |
| Pressure range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Not included (J) |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 170 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR200 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR200 | GA200 series air regulator — sets the port range and weight class. |
|---|---|
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| L | Lower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure). |
| J | No bracket (J) — panel mount or existing bracket. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR200-06 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR200 · 1/8" · 170 g |
|---|---|
| One size up | GAR300 |
| Add filtration | GAFR200-06 (filter + regulator) |
Set a gentle, repeatable clamp force on a small fixture or work-holding device without over-stressing delicate parts. The L type's fine resolution over 0.05-0.4 MPa gives you precise control.
Feed a stable low-pressure air supply to a laboratory instrument, a pneumatic actuator, or a test rig that needs a consistent 0.05-0.4 MPa input. The self-locking knob keeps the setting stable during experiments.
Regulate air to one small pneumatic tool or a spray gun that requires a low, steady pressure. The 1/8" port connects directly to the tool line, and the compact 170 g body mounts easily on a panel.
Choose this GAR20006LJNK when you need fine control over a low-pressure band from 0.05-0.4 MPa (7-58 psi) for a small, precise application. The 1/8" port and 170 g weight suit compact fixtures or single tools; if you need a higher flow, step up to the GAR300 body at 300 g with a 1/4" port. The L type cannot reach a 0.5-0.6 MPa setpoint, so for standard machine pressures select the S type instead. This model has no gauge, so read pressure on your line's own panel gauge, and no bracket, so use a panel mount or existing bracket. The PT thread reads MPa/psi on any fitted gauge. A reflux (K) valve is attached. For clean air, use a GAFR or a GAF filter upstream. The S type's 0.05-0.9 MPa band is about 2.4x this L type's adjustable span.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR200-06 filter-regulator as your air-prep needs grow.
The GAR20006LJNK is a lower-pressure (L) regulator with a 1/8" port and a weight of 170 g. It regulates air from 0.05-0.4 MPa (7-58 psi). The maximum supply pressure is 1.0 MPa (145 psi), and the proof pressure is 1.5 MPa (215 psi). The operating temperature range is -20 to 70 C. It has no gauge, no bracket, and includes a reflux valve.
The 'N' means no circular pressure gauge is fitted, so you must read the downstream pressure on a panel gauge in your line. The 'J' means the mounting bracket is not included, so you will need to use a panel mount or an existing bracket. The 'K' indicates a reverse-flow (reflux) valve is attached.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.