The AirTAC Airtac GAR Air Regulator GAR20006SJN is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.9 MPa range, with 1/8" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR20006SJN is a compact air pressure regulator that takes a variable supply and holds a steady downstream pressure you set with its self-locking knob. This 1/8in unit weighs just 170 g, so it suits small panels and tight spaces without needing extra support. It does not filter or clean the air - it only regulates pressure.
This standard-type model regulates from 0.05-0.9 MPa (7-130 psi), with a maximum supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The pressed-in self-locking mechanism keeps your setpoint stable against vibration and accidental knocks. With no gauge fitted, you read the pressure on your line's own panel gauge.
| Model | Airtac GAR Air Regulator GAR20006SJN |
|---|---|
| Series | GAR200 air regulator |
| Port size | 1/8" (PT thread) |
| Regulation type | Standard |
| Pressure range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Not included (J) |
| Reflux valve | None |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 170 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR200 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR200 | GA200 series air regulator — sets the port range and weight class. |
|---|---|
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| S | Standard regulation: 0.05 - 0.9 MPa (7 - 130 psi). This body offers S (standard) or L (lower pressure). |
| J | No bracket (J) — panel mount or existing bracket. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow (reflux) valve. |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR200-06 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR200 · 1/8" · 170 g |
|---|---|
| One size up | GAR300 |
| Add filtration | GAFR200-06 (filter + regulator) |
Set a precise 0.3 MPa for a small pneumatic clamp on a benchtop fixture. The self-locking knob holds the setting even with machine vibration nearby.
Regulate supply to a small air tool like a die grinder or blow gun. The 1/8in port matches light-duty tooling, and the compact 170 g body mounts easily.
Stabilize a variable shop line down to a consistent 0.2 MPa for a lab fixture or test jig. The balanced design keeps the setpoint steady as supply pressure fluctuates.
Choose the GAR20006SJN when you need a 1/8in regulator for low-flow applications like a single clamp or a small tool. The J code means no mounting bracket is included, so plan for panel mounting or use an existing bracket. The N code means no gauge is fitted - rely on your line's panel gauge instead. This unit uses PT threads with an MPa/psi gauge scale if you add one later. If your air needs cleaning, pair this with a GAF filter upstream or step up to a GAFR200-06 filter-regulator. The S type's adjustable band spans 0.85 MPa, which is about 2.4x the 0.35 MPa band of the L type.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR200-06 filter-regulator as your air-prep needs grow.
The GAR20006SJN regulates air from 0.05-0.9 MPa (7-130 psi). Maximum supply pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and operating temperature is -20 to 70 C. The unit weighs 170 g and has a 1/8in port. It has no gauge and no bracket.
The N means no pressure gauge is fitted. You read the downstream pressure on your line's own panel gauge instead. The regulator still functions exactly the same, just without the built-in circular gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.