The AirTAC Airtac GAR Air Regulator GAR20006SJNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.9 MPa range, with 1/8" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR20006SJNK is an air pressure regulator that takes a higher supply pressure and holds a steady, lower downstream pressure you set with the knob. It does not filter, clean, or dry the air, and has no drain bowl or filter element. This unit uses a 1/8in port and weighs 170 g, making it the lightest body in the GAR range.
This standard type regulates from 0.05-0.9 MPa (7-130 psi) and includes a pressed-in self-locking knob that stops the set pressure drifting from vibration or accidental knocks. The balanced adjustment mechanism holds the setpoint as supply pressure varies. No gauge is fitted, so pressure is read on the line's own panel gauge.
| Model | Airtac GAR Air Regulator GAR20006SJNK |
|---|---|
| Series | GAR200 air regulator |
| Port size | 1/8" (PT thread) |
| Regulation type | Standard |
| Pressure range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Not included (J) |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 170 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR200 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR200 | GA200 series air regulator — sets the port range and weight class. |
|---|---|
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| S | Standard regulation: 0.05 - 0.9 MPa (7 - 130 psi). This body offers S (standard) or L (lower pressure). |
| J | No bracket (J) — panel mount or existing bracket. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR200-06 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR200 · 1/8" · 170 g |
|---|---|
| One size up | GAR300 |
| Add filtration | GAFR200-06 (filter + regulator) |
Set a steady 0.3 MPa for a small pneumatic clamp on a benchtop fixture. The 1/8in port handles the low air demand of a single actuator, and the self-locking knob keeps the setting stable during repeated cycles.
Regulate supply to a handheld air tool at a workbench. The 170 g body mounts easily on a small panel, and the no-gauge design suits a line that already has a panel gauge for monitoring.
Use in a lab or prototype setup to provide a stable test pressure to a small valve manifold. The compact size fits tight spaces, and the reflux valve is attached for the specified configuration.
Choose the body and port first: GAR200 offers 1/8in or 1/4in ports at 170 g, while the next size up GAR300 weighs 300 g and starts at 1/4in. This model is the standard type (S) with a 0.05-0.9 MPa range, not the lower type (L) that only reaches 0.4 MPa. The J code means no mounting bracket is included, so plan for panel mounting or an existing bracket. The N code means no gauge is fitted, and the PT thread reads MPa/psi on any line gauge. The K code attaches a reverse-flow (reflux) valve, which is named here but not detailed in our data. If the line also needs clean air, use the matching GAFR200-06 or a GAF filter upstream, since this regulator does not clean the air. The S type's adjustable band is about 2.4x the L type's (0.85 MPa vs 0.35 MPa).
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR200-06 filter-regulator as your air-prep needs grow.
The GAR20006SJNK is a standard type regulator with a 1/8in port and a weight of 170 g. It regulates from 0.05-0.9 MPa (7-130 psi), with a max supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -20 to 70 C. It has no gauge and no bracket, with a PT thread and a reflux valve attached.
The N code means no gauge is fitted, so you read pressure on the line's own panel gauge instead. The J code means no mounting bracket is included, so you need to use panel mounting or an existing bracket. This reduces cost and weight for installations that already have these components.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.