The AirTAC Airtac GAR Air Regulator GAR20008LJNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/4" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR20008LJNK is a compact air pressure regulator from AirTAC's GAR200 series, designed to take a higher supply pressure and hold a steady, lower downstream pressure that you set with its knob. It is a regulator only - it does not filter, clean, or dry the air, and it has no drain bowl or filter element. This unit weighs 170 g and has a 1/4 inch port, making it a lightweight choice for small pneumatic circuits.
This lower-pressure (L) model regulates from 0.05 to 0.4 MPa (7-58 psi), a band suited for delicate low-force tasks. The pressed-in self-locking knob prevents the set pressure from drifting due to vibration or accidental knocks, keeping your process stable. With no gauge fitted, you would read the pressure on the line's own panel gauge.
| Model | Airtac GAR Air Regulator GAR20008LJNK |
|---|---|
| Series | GAR200 air regulator |
| Port size | 1/4" (PT thread) |
| Regulation type | Lower pressure |
| Pressure range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Not included (J) |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 170 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR200 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR200 | GA200 series air regulator — sets the port range and weight class. |
|---|---|
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| L | Lower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure). |
| J | No bracket (J) — panel mount or existing bracket. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR200-08 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR200 · 1/4" · 170 g |
|---|---|
| One size up | GAR300 |
| Add filtration | GAFR200-08 (filter + regulator) |
Set a gentle, repeatable clamping pressure for fragile parts on a small assembly fixture, where a standard regulator's higher range would risk damage.
Regulate air for a sensitive laboratory instrument or a pneumatic actuator on a test bench, holding a stable low pressure for accurate experiments.
Feed a small air tool or a spray gun with a consistent low pressure, preventing over-pressurization and improving control during detailed work.
Choose the GAR20008LJNK when you need precise low-pressure regulation in a small footprint. The 1/4 inch port and 170 g mass suit it for compact machines or individual tools; if you need more flow, step up to the GAR300 body at 300 g. This L type regulates 0.05-0.4 MPa (7-58 psi), so it cannot reach a 0.5-0.6 MPa setpoint - pick the S type for standard pressures. The J code means no mounting bracket is included, so plan for panel mounting or an existing bracket. The N code means no gauge is fitted; the PT thread reads MPa/psi if you add one. A reflux (K) valve is attached, and it is named here only. If your line also needs clean air, use a GAFR or a GAF filter upstream, as this unit does not filter. The L type's 0.35 MPa adjustable span is about 2.4x narrower than the S type's 0.85 MPa band.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR200-08 filter-regulator as your air-prep needs grow.
The GAR20008LJNK regulates air from 0.05 to 0.4 MPa (7-58 psi). Its maximum supply pressure is 1.0 MPa (145 psi), and its proof pressure is 1.5 MPa (215 psi). It operates in temperatures from -20 to 70 C and weighs 170 g. It has a 1/4 inch port, no gauge, no bracket, and a PT thread.
The 'L' type means it is a lower-pressure regulator, with a range of 0.05-0.4 MPa (7-58 psi), offering finer resolution over that low band compared to the standard type. The 'N' means no pressure gauge is fitted, so you would need to use a line gauge or install one to monitor the output pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.