The AirTAC Airtac GAR Air Regulator GAR40010SNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.9 MPa range, with 3/8" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR40010SNK is an air pressure regulator that takes a variable supply and holds a steady downstream pressure you set with its knob. It does not filter or clean the air, and it has no drain bowl or filter element - it only regulates pressure.
This standard-type unit suits 3/8" ports and weighs 570 g, placing it in the mid-size class. Its pressed-in self-locking knob prevents the setpoint from drifting due to vibration, so a calibrated pressure stays put during a shift.
| Model | Airtac GAR Air Regulator GAR40010SNK |
|---|---|
| Series | GAR400 air regulator |
| Port size | 3/8" (PT thread) |
| Regulation type | Standard |
| Pressure range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Included |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 570 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR400 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR400 | GA400 series air regulator — sets the port range and weight class. |
|---|---|
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| S | Standard regulation: 0.05 - 0.9 MPa (7 - 130 psi). This body offers S (standard) or L (lower pressure). |
| (blank) | Mounting bracket included. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR400-10 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR400 · 3/8" · 570 g |
|---|---|
| One size down | GAR300 |
| One size up | GAR500 |
| Add filtration | GAFR400-10 (filter + regulator) |
Set a steady 0.4 MPa to a coolant valve on a milling center, keeping the spray consistent despite compressor swings.
Hold 0.3 MPa for a pneumatic screwdriver on a bench, so torque stays repeatable across a production run.
Regulate a 0.7 MPa supply down to 0.2 MPa for a leak-test fixture, with the no-gauge design relying on a separate panel meter.
Choose this GAR400 when your line uses 3/8" ports and needs a regulated range of 0.05-0.9 MPa. The standard S type covers the full band, while an L type would cap at 0.4 MPa and cannot reach a 0.5-0.6 MPa setpoint. This model has no gauge, so read pressure on the line's own panel gauge, and it includes the mounting bracket. The PT thread gives an MPa/psi gauge scale if you add one later. A reflux (K) valve is attached, and since this is a regulator only, fit a GAF or GAFR upstream if the air also needs cleaning. The S type's adjustable band is about 2.4x the L type's span (0.85 MPa vs 0.35 MPa).
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR400-10 filter-regulator as your air-prep needs grow.
The GAR40010SNK regulates air from 0.05-0.9 MPa (7-130 psi), with a max supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -20 to 70 C and weighs 570 g with a 3/8" port.
The N in the code means no gauge is fitted, so you read pressure on the line's own panel gauge instead. The K indicates a reverse-flow (reflux) valve is attached, which is named here but not detailed in our data.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.