The AirTAC Airtac GAR Air Regulator GAR40015LN is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/2" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR40015LN is a regulator-only unit that takes a higher supply pressure and holds a steady lower downstream pressure you set with its knob. It does not filter or clean the air, so any water or particles in the line must be handled by a separate filter upstream.
This model has a 1/2in port and weighs 570 g, placing it in the mid-size GAR400 class. It is the lower-pressure L type, regulating from 0.05-0.4 MPa (7-58 psi), and comes without a gauge so you read pressure on the line's own panel gauge. The pressed-in self-locking knob keeps the setpoint from drifting due to vibration.
| Model | Airtac GAR Air Regulator GAR40015LN |
|---|---|
| Series | GAR400 air regulator |
| Port size | 1/2" (PT thread) |
| Regulation type | Lower pressure |
| Pressure range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Included |
| Reflux valve | None |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 570 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR400 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR400 | GA400 series air regulator — sets the port range and weight class. |
|---|---|
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| L | Lower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure). |
| (blank) | Mounting bracket included. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow (reflux) valve. |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR400-15 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR400 · 1/2" · 570 g |
|---|---|
| One size down | GAR300 |
| One size up | GAR500 |
| Add filtration | GAFR400-15 (filter + regulator) |
Set a delicate 0.2 MPa clamp force on a light assembly fixture where a standard regulator would risk over-pressuring the part.
Hold a stable 0.3 MPa supply for a laboratory pneumatic actuator that needs a gentle, repeatable force without a gauge on the unit.
Maintain a low 0.15 MPa pressure for a small spray gun in a finishing station, using the line's own panel gauge for setup.
Choose the GAR400 body when you need a 1/2in port and a 570 g unit that suits medium air demand. The L type regulates only 0.05-0.4 MPa (7-58 psi), so it cannot reach a 0.5-0.6 MPa setpoint; pick the standard S type if you need up to 0.9 MPa. This model has no gauge (N), so rely on an existing panel gauge, and the mounting bracket is included. The PT thread gives a gauge scale reading MPa/psi. If the line also needs clean air, use the matching GAFR400-15 or a GAF filter upstream. The S type's 0.05-0.9 MPa band spans about 2.4x this L type's 0.05-0.4 MPa range.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR400-15 filter-regulator as your air-prep needs grow.
The GAR40015LN is an AirTAC regulator-only unit with a 1/2in port and a weight of 570 g. It regulates air from 0.05-0.4 MPa (7-58 psi), with a maximum supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -20 to 70 C and has no gauge fitted.
The N in GAR40015LN means no gauge is included, so you read the downstream pressure on the line's own panel gauge instead. The L type is the lower-pressure version, regulating only 0.05-0.4 MPa (7-58 psi) for finer control in that low band; it cannot reach higher setpoints like 0.6 MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.