verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC SGC Series · Large-Bore ISO 15552 Cylinder

Airtac SGCD Dual Rod Cylinder SGCD250X40S

The AirTAC Airtac SGCD Dual Rod Cylinder SGCD250X40S is a genuine double acting, double rod ISO 15552 (orig. ISO 6431) tie-rod air cylinder with a Ø250mm bore and 40mm stroke, G1 air ports and adjustable end cushioning. Its large-bore tie-rod build delivers high thrust and drops into standardized ISO 15552 mounting on heavy automation.

  • BoreØ250 mm
  • Stroke40 mm
  • Port sizeG1
  • Acting typeDouble acting, double rod
  • Rod threadM42×2.0
  • CushionAdjustable, 60 mm
$800.24 $807.74 Made to order — confirm lead time
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac SGCD Dual Rod Cylinder SGCD250X40S

Delivering 23562 N of thrust in both directions at 0.5 MPa, this large-bore ISO 15552 tie-rod cylinder uses a twin-rod piston to guarantee equal push and pull force. The symmetric load path prevents rod twisting under heavy offset loads. It yields a safe working load of roughly 14137 N, easily lifting a 1201 kg vertical mass with a 2:1 safety margin. A G1 air port feeds the 250 mm bore.

Four steel tie rods clamp the aluminum barrel for high structural rigidity. Because this is a 250 mm bore, TPU seals are unavailable; standard NBR packings handle the -20 to +70 C range, with a Viton H option for 0-150 C heat. The built-in -S magnet directly supports CMSG, DMSG, and EMSG electronic or reed switches for end-of-stroke sensing.

Airtac SGCD Dual Rod Cylinder SGCD250X40S Technical Specifications

ModelAirtac SGCD Dual Rod Cylinder SGCD250X40S
SeriesSGC ISO 15552 tie-rod cylinder
Bore sizeØ250 mm
Stroke40 mm
Acting typeDouble acting, double rod
Port sizeG1
Rod threadM42×2.0
FluidAir (filtered by 40µm element)
Operating pressure0.15 – 1.0 MPa
Proof pressure1.5 MPa
Temperature-20 to +70 °C
Speed range30 – 500 mm/s
CushionAdjustable, 60 mm
Max standard strokeUp to 1500 mm

Specifications follow the official AirTAC SGC datasheet and ISO 15552 dimensions. Confirm against the product label before installation. Thread options: PT (blank) / G. TPU seals are not available for the Ø250 bore (NBR / Viton only).

Theoretical Output Force (Ø250mm)

PressureForce (both ways)
0.5 MPa23562 N23562 N
0.7 MPa32987 N32987 N
Max (@1.0 MPa)5006 kgf

Double-rod: the rod passes through both covers, so output force is equal in both directions.

Model Code: Airtac SGCD Dual Rod Cylinder SGCD250X40S

SGCDISO 15552 tie-rod cylinder (double-rod type).
250Bore size in mm (125 / 160 / 200 / 250).
×40Stroke length in mm.
-SOptional built-in magnet for CMSG / DMSG / EMSG sensors.

SGC-family variants: SGC (double acting), SGCD (double rod), SGCJ (adjustable stroke). Mounting: LB / FA / FB / CA / CB / CR / TC / FTC / TCM1 / TCM2. Seals: TPU (blank) / Viton H / NBR N.

Where the Airtac SGCD Dual Rod Cylinder SGCD250X40S Is Used

precision_manufacturing

Twin-Spindle Press

Drives two opposing forming tools simultaneously with perfectly synchronized 23562 N force, using the through-rod design to keep pressure balanced.

vertical_align_bottom

Heavy Stamping Anvil

Provides non-rotating, anti-twist downward pressure for large metal stamping operations where a single rod might bind under offset loads.

conveyor_belt

Symmetric Divert Gate

Uses the rear rod extension to mount a cam for DMSG sensors while the front rod pushes a heavy diverting flap on the production line.

Is the Airtac SGCD Dual Rod Cylinder SGCD250X40S the Right Cylinder?

As the largest standard bore, this 250 mm unit sits at the high edge of the SGCD range, dwarfing the 200 mm option which provides 15079 N both ways at 0.5 MPa. If 23562 N is excessive, step down to the 160 mm bore yielding 9425 N. Choose the double-rod layout when your mechanism demands anti-rotation guidance, twin tooling driven from both ends, or a rear sensor cam. Mounting hardware includes FA, LB, TC, FTC, TCM1, and TCM2 brackets. The -S magnet enables position detection. Although the 40 mm stroke is short, always support side loads with external guide rails for any cylinder stroke approaching 500 mm or more.

Quick checklist

  • ✓ Required force at your working pressure
  • ✓ Stroke and mounting space
  • ✓ Port/thread type (PT / G / NPT)
  • ✓ Magnet (-S) for sensors?
  • ✓ Long-stroke side load — support the rod end
Ask an Engineer

Installation & Maintenance Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 1.0 MPa operating pressure.
  • check Avoid side load; support long strokes at the rod end.
  • check Set cushions to minimum, then release gradually.
  • check Use correct mounting accessory (LB/FA/FB/CA/CB/CR/TC).
  • check Installation by qualified personnel per AirTAC docs.

Airtac SGCD Dual Rod Cylinder SGCD250X40S FAQ

Force is equal both ways because the rod exits both ends. It generates 23562 N at 0.5 MPa and 32986 N at 0.7 MPa. The theoretical maximum is 4805 kgf at 1.0 MPa. The air port size is G1.

No, a plain cylinder drifts without live air, and the 60 mm adjustable cushions only decelerate near stroke end. For a held vertical load, install an external rod lock or a pilot-operated check valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Made to Order

Large-bore cylinders built to order — confirm lead time.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Related AirTAC SGC Cylinders

Request a Quote for Airtac SGCD Dual Rod Cylinder SGCD250X40S

Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for SGCD250X40S and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.