The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF100X1000S-10B is a genuine double-acting ISO 15552 cylinder with a Ø100mm bore, 1000mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF100X1000S-10B is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. This specific SKU is configured with a PT3/8 valve port, a 1/2 cylinder port, and a DC24V terminal electrical entry drawing 3.0 W. The built-in valve boasts a 30.0 mm2 orifice (Cv 1.68) and cycles up to 4 times per second. Because the valve operates at 0.15-0.8 MPa, the practical working pressure for this assembled unit is 0.15-0.8 MPa, even though the bare cylinder rates to 1.0 MPa. The 100mm bore generates 3927N of push force at 0.5 MPa.
By integrating the valve directly on a manifold block with O10xO6.5 PU tubing, this unit switches itself from a single coil signal without needing a remote valve. This saves panel space and tubing, making it highly effective for decentralized stations across large machines. The factory setting retracts the piston rod when the coil is energised, but you can reposition the valve to extend-when-energised. A magnet is included for CMSE reed and DMSE electronic sensors.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF100X1000S-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 1000 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/2 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 100×1000 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large factory layouts where running individual valve tubing back to a main manifold is costly. The integrated 4M310 valve lets this 100mm bore cylinder operate independently from a single DC24V signal.
Provides 3927N of push force at 0.5 MPa for pressing and joining operations. The built-in valve ensures rapid 4 cycle/sec switching without needing a separate external valve bank.
Perfect for upgrading older equipment where panel space is scarce. The manifold block and short PU tubing eliminate the need to plumb a remote valve, simplifying installation.
Choose this 100mm bore when you need heavy thrust up to 3927N at 0.5 MPa; if your application requires less force, stepping down to the 80mm bore yields 2513N push force at 0.5 MPa while saving envelope space. A self-valved SAIF beats a separate cylinder plus remote valve in space-tight machines by eliminating long pneumatic tubing runs and extensive wiring. For load-holding requirements, remember the 5/2 valve routes air but does not lock the load; consider the SAIL series for pneumatic locking. When replacing this unit, match the 1000mm stroke, 1/2 cylinder port, PT3/8 valve port, DC24V terminal coil, and -S magnet. Because the stroke is 1000mm, ensure adequate guide support to prevent rod side-loading and premature seal wear.
Quick checklist
The 100mm bore generates 3927N push force and 3681N pull force at 0.5 MPa. The built-in 4M310-10 valve has a 30.0 mm2 orifice with a Cv of 1.68, ensuring high flow for the cylinder.
Yes. The factory setting retracts the rod when the DC24V coil is energised, but you can reconfigure it to extend-when-energised by repositioning the 5/2 valve. This eliminates the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.