The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF100X500-10B is a genuine double-acting ISO 15552 cylinder with a Ø100mm bore, 500mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF100X500-10B is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. This specific build pairs a 100mm bore with a 500mm stroke, utilizing a carbon steel piston rod and PT tapered port threads. The built-in valve offers an effective area of 30.0 mm2 (Cv 1.68) and operates via a DC24V terminal connection drawing 3.0 W. Because the manifold routes air directly through PU tubing (O10 x O6.5), the CYLINDER port (PT3/8) is distinct from the VALVE port (10, or 3/8).
While the bare cylinder rates to 1.0 MPa, the practical operating range for this assembled SAIF unit is 0.15-0.8 MPa due to the internal pilot valve limits. Delivering 3927N of push force at 0.5 MPa, it switches itself from one coil signal, eliminating remote plumbing. By factory default, the piston rod retracts when the coil is energised, but you can reposition the valve to extend-when-energised. The unit achieves a 0.05s response time with IP65 protection.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF100X500-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 500 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/2 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 100×500 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large-scale production lines where installing a central valve island is impractical. The integrated 4M310-10 valve allows this 100mm bore cylinder to operate independently from a single DC24V signal.
Provides 3927N of push force at 0.5 MPa for moving heavy pallets or actuators. The 500mm stroke handles long transfer distances without requiring a remote valve setup.
Perfect for upgrading older machinery where routing new pneumatic tubing is restricted. The built-in manifold and terminal electrical entry minimize both air and wiring footprint.
Choose this 100mm bore when a 63mm cylinder (providing 1559N push at 0.5 MPa) cannot meet your thrust requirements, but be mindful of the larger envelope. The self-valved SAIF architecture is ideal for decentralized stations across large machines where running separate valve tubing is costly and consumes panel space. With a 500mm stroke, you must account for side-load conditions; ensure proper guide rails to prevent rod binding.
When ordering a replacement, verify the 100mm bore, 500mm stroke, 4M310-10 valve port, DC24V voltage, terminal electrical entry, and PT thread. Note that the 5/2 valve routes air but does not lock the load mechanically; if you need position holding without live pressure, consider the SAIL lock series instead. A magnet (-S) is not included on this SKU.
Quick checklist
The 100mm bore generates 3927N of push force and 3681N of pull force at 0.5 MPa. The integrated 4M310-10 5/2 valve has an effective area of 30.0 mm2 (Cv 1.68) with a maximum frequency of 4 cycles per second.
It uses a DC24V terminal coil drawing 3.0W with IP65 protection and a 0.05s response time. By factory default, the rod retracts when the coil is energised, but you can reconfigure it to extend-when-energised by repositioning the valve. No separate remote valve is needed.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.