The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF100X700S-10A is a genuine double-acting ISO 15552 cylinder with a Ø100mm bore, 700mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF100X700S-10A is a double-acting ISO 15552 profile cylinder with an integrated 4M310-10 5/2 solenoid valve. This built-in valve provides a Cv of 1.68 and an effective orifice of 30.0 mm2, driving the 100mm bore to a substantial 3927N push force at 0.5 MPa. Equipped with a PT3/8 cylinder port and a PT3/8 valve port, it features an AC220V terminal coil drawing 3.5 VA with an IP65 rating and a 0.05s activation time. The manifold connects to the cylinder via O10xO6.5 PU tubing.
Because the cylinder body rates to 1.0 MPa but the 4M310 valve operates internally piloted at 0.15-0.8 MPa, the practical working range for this assembled SAIF unit is 0.15-0.8 MPa. The factory setting retracts the piston rod when the coil is energised, but you can reposition the valve to extend-when-energised if your logic requires it. The included -S magnet works seamlessly with AirTAC CMSE reed and DMSE electronic sensors for precise positioning feedback.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF100X700S-10A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 700 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/2 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 100×700 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates remote valve plumbing by switching high-force 100mm actuators directly at the station using a single AC220V signal.
Provides up to 3927N of push force at 0.5 MPa for clamping or pressing heavy assemblies over a 700mm travel distance.
Integrates the 4M310-10 valve and manifold directly on the profile barrel, bypassing the need for bulky external valve banks.
Choose this 100mm bore if you need maximum push force (3927N at 0.5 MPa, or 801kgf max at 1.0 MPa) and require a 700mm stroke; stepping down to an 80mm bore drops the 0.5MPa push force to 2513N. A self-valved SAIF excels in decentralized installations across large machines, eliminating the need to run long pneumatic lines back to a remote valve island and saving substantial panel space. For this 700mm stroke, ensure you provide adequate external guide bearings to handle side loads, as the integrated air cushion only decelerates the piston near the stroke ends and does not lock or hold the load. To replace this unit, match the 100mm bore, 700mm stroke, 10 (3/8") valve port, AC220V terminal coil, PT thread, and the -S magnet.
Quick checklist
The 100mm bore generates a push force of 3927N and a pull force of 3681N at 0.5 MPa. At the maximum cylinder pressure of 1.0 MPa, it can deliver up to 801kgf, though the practical operating pressure is limited to 0.15-0.8 MPa by the built-in 4M310 valve.
No, the 4M310-10 valve is internally piloted and switches the cylinder directly from one AC220V coil signal. By default, the rod retracts when energised, but you can reposition the valve to extend-when-energised without adding external pilot lines.