The AirTAC AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCEI) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
A 3/2 valve either feeds its outlet or vents it, and the 3V110-06NCEI does so in the normally closed direction: no air at the outlet until the AC24V coil is switched on. What sets this code apart is the electrical entry - a flying lead arrives pre-wired, so the panel builder connects two wires rather than fitting and seating a separate DIN socket.
You are buying a genuine AirTAC component. Elsewhere in the family you will find the normally open counterpart, all five standard coil voltages, DIN-plug variants, and 3V-F manifold bases for mounting several valves on a single air feed. Datasheet figures such as pressure range and coil power are not published on this page; ask by RFQ and we will confirm them from the manufacturer documentation.
| Model | AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCEI) |
|---|---|
| Series | 3V110 |
| Valve type | 3/2-way (3-port, 2-position) |
| Initial state | Normally closed |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V110 | Body. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Venting a suction cup on a small laboratory pick-and-place gantry, so the held part drops the instant the coil de-energises.
Firing a short blast of air that nudges a package off a conveyor at a sorting station, one valve per diverter point.
Dropping into an existing control cabinet where flying leads save the electrician from fitting DIN sockets for each new valve.
Decide the state first: normally closed holds the outlet vented until the coil is powered, normally open the reverse, and this code is the closed one. Next the electrical connection: the flying lead on the 3V110-06NCEI arrives pre-terminated, which is quicker to wire than a DIN socket but less convenient if you swap coils often. The AC24V coil cannot be field-converted to another voltage, so check your panel supply before ordering. The 1/8in port is the smaller step in the family - suited to compact single-acting actuators, clamps and blow lines. We do not hold flow or pressure data for this family, so send us your cylinder details by RFQ and we will confirm sizing from the datasheet; buyers who want figures published on the page itself should look at the documented AirTAC 3V2 or 3V3 bodies. To drive a double-acting cylinder you need a 5-port valve - see the AirTAC 4V range.
Confirm before you order
Ask us by RFQ and we will read them from the datasheet and reply in writing - we prefer that to publishing a figure we cannot verify. Buyers who need those numbers on the product page itself can choose the documented AirTAC 3V2 (1/8in, 1/4in) or 3V3 (1/4in) series instead.
This is a normally closed valve, so a power loss leaves the outlet vented and a spring-return cylinder free to retract. The flying lead is the electrical entry: the coil comes with pre-wired leads you connect directly, instead of seating a separate DIN plug connector.