AirTAC 3V110 · 3/2-Way Solenoid Valve

AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI)

The AirTAC AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryFlying lead (lead-out wire type)
  • Series3V110
$28.65 $33.05Save 13% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI)

The 3V11006NCFI is a 3-port, 2-position solenoid valve: supply, outlet and exhaust, with two states that either feed the outlet or vent it. This one is normally closed, so the outlet stays vented and the connected single-acting cylinder or air line stays still until the coil is energised. The coil runs on DC12V and arrives with a flying lead, so it can be wired straight into a low-voltage or battery-backed circuit without fitting a DIN connector.

It is a genuine AirTAC part from the 3V1 family, which also covers normally open versions, coils in AC220V, DC24V, AC110V, AC24V and DC12V, DIN-plug and flying-lead entries, and 3V100M manifold bases for mounting several valves on one shared air feed. Datasheet figures such as pressure and flow are not printed here; ask and we will retrieve them from the official documentation for you.

AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI) Technical Specifications

ModelAirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI)
Series3V110
Valve type3/2-way (3-port, 2-position)
Initial stateNormally closed
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryFlying lead (lead-out wire type)
Coil powerConfirm from the datasheet — ask us
Operating pressureConfirm from the datasheet — ask us
Flow coefficientConfirm from the datasheet — ask us
TemperatureConfirm from the datasheet — ask us
ProtectionConfirm from the datasheet — ask us
We do not publish figures we cannot stand behind. We stock this code and ship it as a genuine AirTAC part, but we do not hold a specification sheet for the 3V110 family. Operating pressure, flow, coil power, protection rating and temperature are therefore not printed here — send us the model and we will confirm them from the factory datasheet, usually within 7-8 hours.

Model Code: AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI)

3V110Body.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI) Is Used

cable

Low-voltage control cabinet

A DC12V battery-backed control circuit can switch this valve directly, with the flying lead spliced into the wiring without any DIN connector to fit.

bolt

Single-acting clamp on a workholding fixture

The spring-return clamp receives air only while the coil is energised and vents the moment power drops, holding the workpiece only under control.

tune

Pilot stage for a larger main valve

A small 3/2 valve sends an air signal to actuate a bigger directional valve, letting a low-voltage circuit command a large air flow.

Is the AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI) the Right Part?

Start with the rest state: normally closed means no air at the outlet until the coil is energised, which suits a clamp or stopper that must sit still when the control power is off. Then the port: 1/8in PT suits small single-acting cylinders and light blow lines, while a bigger actuator needs the 1/4in (08) or 3/8in (10) bodies. The DC12V coil must match your supply, because coil voltages cannot be changed by rewiring, so order the voltage you actually have. The flying lead gives you pre-wired tails instead of a DIN socket, which is useful in tight panels or on mobile equipment. If you want several valves on one feed, the 3V100M base takes them side by side. One honest note: we hold no published flow figures for this family, so ask us to check sizing against your actuator before ordering - and if you need a 3-port valve with documented flow and coil power today, the AirTAC 3V2 and 3V3 bodies carry them. A double-acting cylinder is a job for the AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI) FAQ

We do not hold a published datasheet for the 3V1 family on this page, so we will not guess numbers. Ask us by RFQ and we confirm pressure range, flow and coil power straight from the AirTAC datasheet. If you need published figures today, the AirTAC 3V2 (1/8in and 1/4in) and 3V3 (1/4in) bodies carry documented flow and coil-power data.

No. A 3/2 valve has one outlet, which is enough for a single-acting, spring-return cylinder or an on/off air line, but a double-acting cylinder needs two outlets so each side can be pressurised in turn. For that job use an AirTAC 4V five-port valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NCFI)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V11006NCFI and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.