The AirTAC AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NO-X0) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
Three ports and two positions make this a 3/2 valve: it either connects the outlet to supply or dumps the outlet to exhaust. The NO version here does the first when de-energised, so air is present at the outlet before any coil power, and energising the coil shuts it off. On a machine whose fail-safe condition is air present at rest, that is exactly the behaviour you want. The port is a 1/8in PT thread and the coil connects through a DIN plug.
As a genuine AirTAC part it sits in the 3V1 family alongside normally closed variants, five coil voltages, flying-lead or DIN-plug entries and 3V100M manifold bases. Numbers like pressure range and flow are deliberately not listed on this page; we confirm them from the datasheet whenever you ask.
| Model | AirTAC 3V110-06 Solenoid Valve, 3V100 Series (3V11006NO-X0) |
|---|---|
| Series | 3V110 |
| Valve type | 3/2-way (3-port, 2-position) |
| Initial state | Normally open |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | Confirm from the datasheet — ask us |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V110 | Body. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Because the valve is normally open, the cooling air blows whenever the coil is off, and the controller energises the coil only to pause the jet.
If mains power fails, the outlet stays fed and a spring-return actuator holds its air-driven position instead of dropping into the vented state.
A single-acting pusher fed through this valve stays extended during a power loss, keeping off-track products from reaching the next station.
Normally open is the key choice here: the outlet is fed while the coil is off, so whatever the valve drives stays in its air-powered state during a power cut. If your fail-safe instead needs the actuator still and vented, take the NC version of the same body. The 1/8in PT port fits small single-acting cylinders, jets and signal lines; step up to a 1/4in or 3/8in body for larger actuators. Coil voltage is not decodable from this code, so tell us your panel supply and we will confirm the right variant - the family covers AC220V, DC24V, AC110V, AC24V and DC12V, all on either a DIN plug or a flying lead. Published flow data is not something we hold for this family, so we will gladly check sizing from the datasheet on request; buyers who want documented numbers today can use the AirTAC 3V2 or 3V3 bodies, and double-acting needs belong with the AirTAC 4V series.
Confirm before you order
Not from this page - we have no published figures for the 3V1 family in hand, and we refuse to estimate. Request them and we will confirm from the AirTAC datasheet. Buyers who need a 3-port valve with published flow and coil power right now can look at the documented AirTAC 3V2 or 3V3 bodies instead.
Ask what must happen when power is lost. A NO valve like the 3V11006NO-X0 leaves the outlet fed at rest, so a spring-return actuator sits in its air-driven position until the coil is energised. An NC valve holds the outlet vented, keeping the actuator still. Match the rest state to your fail-safe requirement, not to price or availability.