The AirTAC Airtac 3V100 Solenoid Valve 3V110M5NCE is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
AirTAC's 3V110M5NCE is a 3/2 solenoid valve: three ports (supply, outlet, exhaust) and two positions, so it either feeds the outlet or vents it. This example is normally closed - the outlet is exhausted until you energise the coil - and carries the M5 port, the compact thread that suits small spring-return cylinders and short pilot lines.
The AC24V coil is a common safety-oriented control voltage in machine panels, and this SKU uses DIN plug entry: the valve seats on a socket base and the connector clips on. It is a genuine AirTAC part, and the wider 3V1 range covers normally open as well as normally closed, five coil voltages, flying-lead or DIN entry, and 3V100M manifold bases. Any datasheet figure you need - pressure, flow, coil power - we will confirm for you on enquiry.
| Model | Airtac 3V100 Solenoid Valve 3V110M5NCE |
|---|---|
| Series | 3V110 |
| Valve type | 3/2-way (3-port, 2-position) |
| Initial state | Normally closed |
| Port size | M5 |
| Thread | PT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V110 | Body. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
When the spray-booth access door opens, power drops and the NC valve dumps the hold-open cylinder, letting the door swing shut.
A bench-top lab press raises and lowers its spring-return ram on a compact M5 valve fed from the lab's 24V AC control circuit.
The valve sends and vents an air pilot signal to a larger process valve, giving the PLC a low-cost remote on/off point.
Start with the state. Normally closed vents the actuator when power drops, which is what most fail-safe interlocks want; normally open keeps supplying, which suits purge or vent-hold duties. M5 is the smallest port in the family - move to 1/8in, 1/4in or 3/8in codes as the actuator grows. Check that your panel really is 24V AC: a DC24V coil will not work on this SKU, and coil voltage is fixed at order time.
Because we have no published flow data for the 3V1 series, let us verify the size against your actuator before ordering. Buyers who need documented figures today are directed to the AirTAC 3V2 and 3V3 bodies; double-acting cylinders belong on the 5-port 4V series instead.
Confirm before you order
This page carries configuration only. Ask us in an RFQ and we will confirm the datasheet figures for the 3V110M5NCE. Need published numbers immediately? The AirTAC 3V2 and 3V3 series have documented flow and coil power figures.
DIN plug entry means the coil sits on a socket base and the connector unplugs for fast coil swaps. Being normally closed, the valve feeds the outlet only while energised and vents the outlet when power is lost. For double-acting cylinders you would need a 5-port 4V valve instead.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.