The AirTAC Airtac 3V100 Solenoid Valve 3V110M5NOE is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
The 3V110M5NOE pairs AirTAC's smallest 3V1 port, M5, with an AC24V coil - a voltage often already present in machine panels from a control transformer. Functionally it is a 3/2 valve in the normally open state: supply, outlet and exhaust, feeding the outlet while de-energised and venting it once the coil is switched on. That suits small single-acting actuators and blow duties where air must flow when power is absent.
Genuine AirTAC part. Within this family the same body is offered normally closed as well, in AC220V, DC24V, AC110V and DC12V variants, with flying-lead entry if you prefer pre-wired cores, and there are 3V-F bases for mounting several valves on one manifold. We do not publish pressure or flow for the 3V1 series here; request the datasheet through an RFQ and we will send the confirmed figures.
| Model | Airtac 3V100 Solenoid Valve 3V110M5NOE |
|---|---|
| Series | 3V110 |
| Valve type | 3/2-way (3-port, 2-position) |
| Initial state | Normally open |
| Port size | M5 |
| Thread | PT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V110 | Body. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A small single-acting cylinder holding a stop raised to meter packs on a food-line conveyor, where the panel already runs on a 24VAC control transformer.
Part ejection beneath a stamping die: the ejector cylinder stays fed while the press is idle, and the energised coil vents it so the pin retracts clear of the tooling.
When a machine guard opens, the coil circuit energises and the valve dumps line air to exhaust, letting the spring-return actuator settle to a safe position.
Start with the port: at M5 this is the most compact valve in the 3V1 range, best matched to small single-acting cylinders, suction cups and short blow lines, while the 1/8, 1/4 and 3/8 port codes serve larger actuators. Then the state: normally open feeds the outlet until the coil energises and vents it - choose the NC version when the outlet must stay dead without power. The AC24V coil belongs on a panel that already carries a 24 volt AC transformer supply; it cannot be rewired for another voltage. Entry here is a DIN plug; flying leads are available as the I variant. A 3V100M base takes several of these valves on one shared feed if you are building a bank.
We do not hold published flow figures for this series, so ask us to verify the datasheet against your actuator before ordering. Need numbers you can cite now? The AirTAC 3V2 and 3V3 3-port bodies have published flow and coil-power figures. And if the actuator is double-acting, no 3/2 valve will do it - move to the AirTAC 4V series.
Confirm before you order
Operating pressure, flow and coil power consumption for the 3V110M5NOE are all read from the manufacturer datasheet once you send an RFQ - we do not estimate them here. If your project needs those numbers published up front, the AirTAC 3V2 and 3V3 3-port series are the documented alternative.
It is, particularly on machines whose control circuit already runs from a 24 volt AC transformer, because it avoids adding a separate DC supply. Match the coil to the panel at order time; a coil cannot be rewired to a different voltage. For grouped mounting, the 3V100M base carries several 3V1 valves on one shared feed.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.