
The AirTAC AirTAC 3V120-06 Solenoid Valve, 3V100 Series (3V12006-X0) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
The AirTAC 3V12006-X0 is a genuine 3/2 solenoid valve on the 3V120 body. A 3/2 valve has three ports - supply, outlet, exhaust - and two states: it either feeds the outlet or vents it to exhaust. This listing carries the 1/8in port on the family's standard PT thread (G and NPT are catalogue options to order). Beyond the body and port, the code as supplied does not encode a rest state, coil voltage or electrical entry, so we leave those fields open rather than guess them.
It is a genuine AirTAC part. In the 3V1 range you can specify NC or NO, five coil voltages (AC220V, DC24V, AC110V, AC24V, DC12V), DIN plug or flying-lead entry, and 3V-F manifold bases for multi-valve builds. Give us the state, voltage and entry you need with your RFQ, and we will confirm the exact variant together with the datasheet figures.
| Model | AirTAC 3V120-06 Solenoid Valve, 3V100 Series (3V12006-X0) |
|---|---|
| Series | 3V120 |
| Valve type | 3/2-way (3-port, 2-position) |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | Confirm from the datasheet — ask us |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V120 | Body. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A bench pneumatic press passes a pilot air signal through a 3/2 valve to the main clamping valve on the downstroke, keeping the control circuit simple.
An automatic screw-feeding station clamps the bracket with a compact spring-return cylinder before the driver head descends, holding the joint square during driving.
A packaging line puffs a short air mark onto film at each cycle to flag the next fold, pulsing the valve from the panel PLC at machine rate.
This page is a buying-path one: the body and the 1/8in port are known, the rest state and coil are not, so start your RFQ with three answers - NC or NO, the panel voltage, and DIN plug or flying lead. NC holds the outlet dead until energised; NO feeds it until then. The 1/8in port serves small and mid-size single-acting cylinders; bigger actuators step to 1/4in or 3/8in. Whatever coil you choose, it must match the supply - there is no rewiring between voltages. A 3/2 valve drives only single-acting (spring-return) loads: double-acting work belongs on a 5-port AirTAC 4V valve, and several valves on one feed are tidier on a 3V100M base. We do not hold flow figures for this family, so ask us to check the valve against your actuator before ordering - or choose the AirTAC 3V2 and 3V3 bodies if you need published flow and coil-power data today.
Confirm before you order
This page carries no pressure, flow, coil-power or dimensional data for the 3V1 family. Send the RFQ and we confirm those from the datasheet, together with the state, voltage and entry for this code. If printed figures are a must before you enquire, the AirTAC 3V2 (1/8in and 1/4in) and 3V3 (1/4in) bodies have published flow and coil-power data.
Decide what the outlet must do on power loss: NC leaves it dead until the coil is energised, NO leaves it fed until then - the fail-safe condition picks the variant. Note also that a 3/2 valve cannot drive a double-acting cylinder; that needs a 5-port AirTAC 4V valve, and multi-valve builds are simpler on a 3V100M manifold base.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.