The AirTAC AirTAC 3V220-06 Solenoid Valve, 3V200 Series (3V22006BI) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
The 3V22006BI is an AirTAC 3/2 solenoid valve with a 1/8 inch PT port, a DC24V coil and a flying-lead electrical entry. A 3/2 valve has three ports - supply, outlet and exhaust - and two positions: energised, it passes air from supply to outlet; de-energised, it vents the outlet to exhaust. That makes it the valve you reach for when a single outlet either needs air or needs to dump it, such as feeding a spring-return actuator, switching a blow-off line, or piloting a larger valve.
We stock this exact SKU as a genuine AirTAC part and ship it as listed: 1/8in port, DC24V, flying lead. The same body family is also available in the other port sizes, both flow states, the remaining four coil voltages, and with a DIN-plug entry instead of leads. Datasheet figures for this family are not published on this page; send us an RFQ and we will confirm the numbers you need before you commit.
| Model | AirTAC 3V220-06 Solenoid Valve, 3V200 Series (3V22006BI) |
|---|---|
| Series | 3V220 |
| Valve type | 3/2-way (3-port, 2-position) |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V220 | Body. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A fixture clamp on a machining cell holds a part with a spring-return cylinder. The 3/2 valve sends air to extend the clamp and vents the line to exhaust when the clamp releases, so the operator hears and sees the state change.
A lab automation line uses a short pulsed air jet to clear debris from a sensor window before each measurement. A 3/2 valve on the 1/8in line gives a simple energise-to-blow, de-energise-to-stop switch driven straight from a 24V DC output.
A packaging machine switches a large air-operated process valve whose actuator needs more pilot flow than a PLC can supply. This 3/2 valve takes the small control signal and passes the main air through to the actuator.
Start with the port. 1/8in is the smaller of the two threaded sizes in this family, which generally pairs with compact single-acting actuators and short air lines; step up to 1/4in or 3/8in if the actuator volume is larger. Next, match the coil to your panel: this SKU is DC24V, and a solenoid coil cannot be rewired to another voltage, so order the letter that matches your supply. The flying-lead entry on this valve arrives pre-wired, which suits tight panels and quick replacements; choose the DIN-plug variant if you prefer a detachable connector.
Because we do not hold published flow figures for this family, ask us to check sizing against your actuator before ordering. If you need a 3-port valve with fully published specifications today, our documented 3V2 and 3V3 bodies carry flow and coil-power figures on their pages. If your cylinder is double-acting, a 3/2 valve will not drive it - you need a 5-port valve from the AirTAC 4V series.
Confirm before you order
We do not publish performance figures for this family on the page because we want every number you read to be one we can stand behind. Send an RFQ and we will confirm pressure range, flow and coil power from the manufacturer datasheet for your specific order. If you need those figures printed in front of you right now, our documented 3V2 and 3V3 series have full published specifications and may suit the application instead.
The code 3V22006BI does not carry an NC or NO state letter, so ask us to confirm the default flow state for this SKU before ordering - we will check it against the datasheet. On function: a 3/2 valve feeds and vents a single outlet, so it suits spring-return cylinders, blow and pilot duty. It cannot drive a double-acting cylinder, which needs simultaneous supply and exhaust on two ports - for that, specify a 5-port valve from the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.