The AirTAC AirTAC 3V220-06 Solenoid Valve, 3V200 Series (3V22006C) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
The 3V22006C is a genuine AirTAC 3/2 solenoid valve with a 1/8in PT port and an AC110V coil behind a DIN plug. AC110V is a common control voltage in plants wired to North American practice and in older installations that never moved to 24V, so this variant drops straight into those panels. As a three-port, two-position valve it connects the outlet either to supply or to exhaust - the single feed-and-vent point a spring-return cylinder or blow circuit needs. The state letter is part of the ordering code, so tell us whether the valve must rest closed or open.
Across the 3V1, 3V2 and 3V3 series AirTAC offers both states, five voltages, DIN or flying-lead entry and manifold bases, so the rest of the machine can be ordered to match. Datasheet values for pressure, flow and coil consumption are not shown here; ask and we will send them.
| Model | AirTAC 3V220-06 Solenoid Valve, 3V200 Series (3V22006C) |
|---|---|
| Series | 3V220 |
| Valve type | 3/2-way (3-port, 2-position) |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V220 | Body. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Older plant wired throughout at 110V AC takes this valve without adding a transformer or a separate 24V supply just for one pneumatically actuated function.
A single-acting cylinder lifts a guide or gate; the valve extends it with air and vents it so the spring can drop it back between cartons.
One coil circuit clamps the workpiece for drilling or grinding, and spring return releases it when the coil drops out.
Check two things before ordering: that your panel really runs 110V AC, because a coil wound for one voltage cannot be reconnected to another, and that a 1/8in PT port is big enough for your actuator - it is the right step for compact single-acting cylinders and short blow lines, while larger actuators step to 1/4in or 3/8in. If you would rather not decide NC versus NO alone, describe the fail-safe behaviour you want and we will name the right order code. We hold no published flow figure for this family, so we will confirm sizing from the datasheet before you commit; where documented figures are needed immediately, the AirTAC 3V2 and 3V3 bodies carry them. Double-acting cylinders remain a job for the 5-port AirTAC 4V series.
Confirm before you order
Not on this page - our data for the 3V family is incomplete and we will not print estimates. Send the RFQ and we will confirm pressure, flow and coil power from the AirTAC datasheet. The 3V2 and 3V3 bodies are the documented 3-port options in the range if you need published figures before ordering.
That depends on the state you order. A normally closed code leaves the outlet vented until the coil pulls in; a normally open code keeps the outlet fed until power arrives. Either way the valve handles a single-acting actuator only - a double-acting cylinder needs both sides pressurised, which is 5-port AirTAC 4V territory.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.