The AirTAC AirTAC 3V310-08 Solenoid Valve, 3V300 Series (3V31008NCF) is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
3V31008NCF is a 3/2 solenoid valve from AirTAC in the normally closed, 1/4in port configuration, with a DC12V coil on a DIN plug. A 3/2 valve has one supply port, one outlet and one exhaust, and two states: it either passes air to the outlet or dumps the outlet to exhaust. De-energised, this valve holds the outlet closed; energise the 12V coil and air flows from supply to outlet. Twelve volts is the classic choice for battery-fed panels and vehicle electrics, provided the supply really is 12V.
This is a genuine AirTAC part. The same body can be ordered normally open, with AC220V, DC24V, AC110V or AC24V coils, with a flying lead instead of the DIN plug, and on a 3V-F manifold base. Flow, pressure and power figures for the 3V310 are not held on this page; request them by RFQ and we will read them off the datasheet for you.
| Model | AirTAC 3V310-08 Solenoid Valve, 3V300 Series (3V31008NCF) |
|---|---|
| Series | 3V310 |
| Valve type | 3/2-way (3-port, 2-position) |
| Initial state | Normally closed |
| Port size | 1/4 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V310 | Body. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Switching the air feed to a blow gun run from a van's battery-fed compressor on a mobile repair round.
Opening a spring-return gate cylinder on a farm grain auger from the tractor's 12V electrical system.
Energising a single-acting hold-down cylinder on an engine test bench wired to a 12V supply.
Match the coil to the supply first: this code carries a DC12V coil, the choice for battery-fed panels and vehicle electrics, and a coil cannot be converted to another voltage later. State is normally closed, so air reaches the outlet only while the coil is energised, and the outlet vents the moment power drops. The 1/4in port suits larger spring-return cylinders and blow lines than the 1/8in step.
Entry is DIN plug; add an I to the code for flying leads. Manifold mounting on a 3V-F base is available when several valves share one machine feed. Flow, pressure and coil-power figures for the 3V1 body are not published on this page, so ask us to confirm them against your actuator on an RFQ. Where you need documented figures today, the AirTAC 3V2 and 3V3 bodies carry them in print - and a double-acting cylinder calls for the 5-port AirTAC 4V series instead.
Confirm before you order
That number lives on the AirTAC datasheet, not on this page - ask us by RFQ and we will confirm the operating pressure, flow and coil draw exactly as published. If you would rather order a body whose figures are already documented, look at the AirTAC 3V2 and 3V3 series.
No. Coil voltage is fixed at manufacture; order the voltage that matches your panel. Across this family you can order AC220V, DC24V, AC110V, AC24V or DC12V coils.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.