verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V320 · 3/2-Way Solenoid Valve

AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0)

The AirTAC AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0) is a genuine 3-port 2-position (3/2) solenoid valve with 3/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.

  • Valve type3/2-way (3-port, 2-position)
  • Port size3/8 in
  • Electrical entryDIN plug (DIN socket type)
  • Series3V320
$50.90 $55.85Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V320-10 valve type, voltage, entry and pilot on one page All 3V320-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0)

The 3V32010 is the wide-port option in the AirTAC 3V320 body: a 3-port, 2-position solenoid valve whose 3/8in outlet accepts the bigger tubing that larger spring-return actuators demand. Its two states give the outlet a simple either-or: fed from supply, or opened to exhaust. That is the whole job of a 3/2 valve, and it is the function behind clamping, blowing and venting circuits.

It is a genuine AirTAC part. Elsewhere in the 3V family you will find normally closed and normally open variants, coils for five voltages, flying-lead as well as DIN plug entry, and 3V-F manifold bases that carry several valves on one supply. This page carries no pressure, flow or power figures; raise an RFQ and the datasheet values follow with our reply.

AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0) Technical Specifications

ModelAirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0)
Series3V320
Valve type3/2-way (3-port, 2-position)
Port size3/8 in
ThreadPT
Coil voltageConfirm from the datasheet — ask us
Electrical entryDIN plug (DIN socket type)
Coil powerConfirm from the datasheet — ask us
Operating pressureConfirm from the datasheet — ask us
Flow coefficientConfirm from the datasheet — ask us
TemperatureConfirm from the datasheet — ask us
ProtectionConfirm from the datasheet — ask us
We do not publish figures we cannot stand behind. We stock this code and ship it as a genuine AirTAC part, but we do not hold a specification sheet for the 3V320 family. Operating pressure, flow, coil power, protection rating and temperature are therefore not printed here — send us the model and we will confirm them from the factory datasheet, usually within 7-8 hours.

Model Code: AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0)

3V320Body.
3/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
—Electrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0) Is Used

engineering

Pneumatic gate or lifter

A larger spring-return actuator raising a guard door or lift table, fed through 3/8in tubing that matches the port.

build

Station air cut-off

Switching one machine station's air leg on and off, and venting it downstream, so maintenance can work on it without shutting the whole line.

science

Bench test stand vent

A lab or QA test stand where a spring-loaded fixture must be fed and then exhausted between test cycles.

Is the AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0) the Right Part?

A 3/8in port is the step for bigger jobs: medium and large single-acting cylinders and higher-demand blow lines. Below it sit the 1/4in, 1/8in and M5 options in the same family. Choose NC if power loss must leave the outlet vented, NO if it must stay fed - both behaviours exist in this body, and the code above does not mark which one you get, so tell us which you need when you enquire. The cleanest path is an RFQ naming 3V32010 together with the actuator it will drive; we will verify sizing from the datasheet rather than guess. Where published flow and coil power are a must-have today, the documented AirTAC 3V2 and 3V3 bodies carry them. And if the actuator is double-acting, this is not your valve - go to the 5-port 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0) FAQ

Not on this page - we only publish figures we can stand behind, and for the 3V320 body those come from the datasheet, which we send with an RFQ reply. The AirTAC 3V2 and 3V3 bodies are the 3-port valves whose flow and coil power are documented up front.

Yes - order a 3V-F manifold base instead of individual plumbing. The base is a machined block carrying several 3V valves on one shared feed, which trims piping and gives fault-finding one place to look; the valves themselves are ordered separately.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010-X0)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V32010-X0 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.