The AirTAC Airtac BSE Clamp Standard Cylinder BSE40X75 is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø16mm rod and holds up to 900 N in either direction — no drift. Ø40mm bore, 75mm stroke, PT1/4 cylinder ports, G1/8 lock-release port.
The AirTAC BSE40X75 is a double-acting ISO 15552 profile cylinder featuring an integrated spring-applied, air-released rod lock. A collet clamps the Ø16 mm piston rod automatically, delivering a 900 N bidirectional static holding force. If air pressure drops or an E-stop trips, the rod stays securely locked at its stopped position.
This fail-safe mechanism relies on a separate G1/8 release port, keeping the lock function entirely distinct from the adjustable air cushions at both ends. Operating pressure is capped at 0.7 MPa, and the cylinder body accepts standard SE mounting accessories except for FTC. This specific SKU lacks a magnet, so it does not support position sensing.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE40X75 holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE40X75 |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø40 mm |
| Stroke | 75 mm |
| Static holding force | 900 N |
| Cylinder port | PT1/4 |
| Lock-release port | G1/8 |
| Rod thread | M12×1.25 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 30 mm |
| Max stroke | Up to 800 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa (max) | 880 N | — |
| Max drive (@0.7 MPa) | 90 kgf | |
Drive force is separate from the 900 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 40 | Bore size in mm. |
| ×75 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a 900 N raised vertical platform securely in place during air loss, preventing sudden descent while handling light materials.
Maintains 900 N of clamping force on a machined part if the main air supply is exhausted, ensuring the workpiece stays fixed for safe clearing.
Provides a hard stop for incoming pallets and locks instantly via the collet if the E-stop is hit, holding the 900 N load without drifting backward.
Verify your load does not exceed the 900 N holding force. If you need less drive force, stepping down to the 32 mm bore yields 402 N push at 0.5 MPa and 600 N holding. If you need more, the 50 mm bore provides 982 N push at 0.5 MPa and 1400 N holding. Always engage the lock only after the rod fully stops, and release it only when piston pressures are balanced, allowing at least 0.5 s before moving. To replace this unit, match the 40 mm bore, 75 mm stroke, PT1/4 port, and basic mounting.
Quick checklist
The spring-applied collet clamps the rod instantly upon air loss, providing a 900 N static holding force. The drive forces are 628 N push and 528 N pull at 0.5 MPa, 879 N push at 0.7 MPa, and a maximum drive of 90 kgf.
No, the 30 mm adjustable air cushions only decelerate the drive motion; the 900 N holding force comes solely from the spring collet. The holding force is fixed by the mechanical lock and cannot be regulated by pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.