The AirTAC Airtac BSE Clamp Standard Cylinder BSE40X800 is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø16mm rod and holds up to 900 N in either direction — no drift. Ø40mm bore, 800mm stroke, PT1/4 cylinder ports, G1/8 lock-release port.
The AirTAC BSE40X800 is a double-acting ISO 15552 profile cylinder featuring an integrated spring-applied, air-released rod lock. A collet clamps the Ø16 mm piston rod, delivering a bidirectional static holding force of 900 N with zero live air. This fail-safe mechanism ensures suspended loads remain exactly where they stopped if air pressure drops or an E-stop is hit.
Operating pressure is capped at 0.7 MPa, and the lock unlocks via a dedicated G1/8 release port. Because it uses the standard SE extruded aluminum body, all SE mounting accessories fit this model except FTC. This specific SKU lacks a magnet, so position sensing is not available without a different variant.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE40X800 holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE40X800 |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø40 mm |
| Stroke | 800 mm |
| Static holding force | 900 N |
| Cylinder port | PT1/4 |
| Lock-release port | G1/8 |
| Rod thread | M12×1.25 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 30 mm |
| Max stroke | Up to 800 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa (max) | 880 N | — |
| Max drive (@0.7 MPa) | 90 kgf | |
Drive force is separate from the 900 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 40 | Bore size in mm. |
| ×800 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a 900 N vertical machining axis safely in place during air loss, preventing a 90 kgf payload from drifting downward.
Keeps a clamped fixture locked on an automated lathe if shop air exhausts, ensuring the workpiece stays secured at 800 mm extension.
Maintains a raised pneumatic pallet gate rigidly in position during an E-stop, resisting dynamic shifts up to 900 N without needing live air.
Verify your suspended load does not exceed the 900 N holding force. If you need less drive force, step down to the BSE32 bore, which provides a 402 N push at 0.5 MPa and a 600 N hold. If your load exceeds the 40 mm bore's 90 kgf maximum drive, step up to the BSE50, offering a 982 N push at 0.5 MPa and a 1400 N hold. Always engage the collet only after the rod completely stops, and release it only when piston pressures are balanced, allowing at least 0.5 s before moving. For this 800 mm stroke, use a guide to prevent side-load damage to the barrel. Match the PT1/4 port, 800 mm stroke, and mounting choice when replacing.
Quick checklist
The drive forces are 628 N push and 528 N pull at 0.5 MPa, 879 N push at 0.7 MPa, and a maximum 90 kgf drive at 0.7 MPa. The separate static holding force of the spring collet lock is 900 N.
If air is lost, the spring collet immediately clamps the rod with 900 N of bidirectional force, holding the load without live air. To release, apply 0.15-0.7 MPa to the G1/8 release port, balance piston pressures, and wait at least 0.5 s before moving.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.