The AirTAC Airtac BSE Clamp Standard Cylinder BSE50X400 is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø20mm rod and holds up to 1400 N in either direction — no drift. Ø50mm bore, 400mm stroke, PT1/4 cylinder ports, G1/8 lock-release port.
The AirTAC BSE50X400 is a double-acting ISO 15552 profile cylinder featuring an integrated spring-applied, air-released rod lock. A collet clamps the Ø20 mm piston rod automatically, providing a bidirectional static holding force of 1400 N. If air pressure drops or an E-stop trips, the lock engages to prevent drift. Operating pressure is capped at 0.7 MPa.
This 50 mm bore, 400 mm stroke unit uses a separate G1/8 release port to unlock the collet. The lock is a holding device, not a dynamic brake; it must engage only after the rod stops. Because it uses the standard SE body, SE mounting accessories fit perfectly, except for the FTC model.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE50X400 holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE50X400 |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø50 mm |
| Stroke | 400 mm |
| Static holding force | 1400 N |
| Cylinder port | PT1/4 |
| Lock-release port | G1/8 |
| Rod thread | M16×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 30 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa (max) | 1374 N | — |
| Max drive (@0.7 MPa) | 140 kgf | |
Drive force is separate from the 1400 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 50 | Bore size in mm. |
| ×400 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a 1400 N vertical load in place if air is lost, preventing a raised pallet from crashing down during an E-stop event.
Clamps the rod securely to lock a tooling head in position, maintaining exact alignment without relying on live air pressure.
Acts as a hard stop that stays firmly put under impact, halting pallet flow securely when the line halts and air exhausts.
Verify your load requires a holding force of 1400 N or less. If you need less drive power, step down to the 40 mm bore (push 628 N at 0.5 MPa, hold 900 N). If your load exceeds 1400 N, step up to the 63 mm bore (push 1559 N at 0.5 MPa, hold 2200 N). Always balance pressures on both sides of the piston before releasing the lock, and allow at least 0.5 s for full release before initiating motion.
For replacement, match the 50 mm bore, 400 mm stroke, PT1/4 cylinder port, and your specific mounting code. This SKU has no -S magnet, so position sensing is not available. At 400 mm stroke, use guide rails to prevent side loads and extend bearing life.
Quick checklist
The spring-applied collet clamp engages instantly, providing a 1400 N bidirectional static hold. The rod stays locked at its stopped position until balanced air is reapplied to the G1/8 release port.
The drive forces are 982 N push and 825 N pull at 0.5 MPa, with a maximum push of 1374 N (140 kgf) at 0.7 MPa. The separate static holding force of the rod lock is 1400 N.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.