The AirTAC Airtac BSE Clamp Standard Cylinder BSE80X125 is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø25mm rod and holds up to 3600 N in either direction — no drift. Ø80mm bore, 125mm stroke, PT3/8 cylinder ports, G1/8 lock-release port.
The AirTAC BSE80X125 is a double-acting, single-rod ISO 15552 profile cylinder featuring an integrated spring-applied, air-released rod lock. A collet mechanism provides a 3600 N bidirectional fail-safe hold, securing the load in both directions if air is lost or an E-stop trips. Operating pressure is capped at 0.7 MPa, and the lock is controlled via a separate G1/8 release port.
This unit uses an extruded aluminum barrel without external tie rods and includes adjustable air cushions at both ends. The lock is a holding device, not a dynamic brake; it must be engaged only after the piston rod stops, and released only when pressures are balanced, allowing at least 0.5 seconds for full release before motion. This SKU ships without a magnet, so position sensing is not supported.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE80X125 holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE80X125 |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø80 mm |
| Stroke | 125 mm |
| Static holding force | 3600 N |
| Cylinder port | PT3/8 |
| Lock-release port | G1/8 |
| Rod thread | M20×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 36 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa (max) | 3519 N | — |
| Max drive (@0.7 MPa) | 359 kgf | |
Drive force is separate from the 3600 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 80 | Bore size in mm. |
| ×125 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a raised pallet stack securely mid-stroke with 3600 N of fail-safe force, preventing a sudden crash if the supply air drops during conveyor transfer.
Maintains vise pressure on an aluminum casting during an air outage, using the collet lock rather than the air cushion to prevent the part from shifting.
Keeps a heavy robotic cell guard fully extended during an E-stop event, locking the 25 mm rod instantly until pressure is restored and balanced.
Verify your load requires a holding force of 3600 N or less. If your drive and hold requirements are lower, the adjacent 63 mm bore offers a 1559 N push at 0.5 MPa and a 2200 N hold. If you need more force, stepping up to the 100 mm bore provides a 3927 N push at 0.5 MPa and a 5500 N hold. The lock engages via spring force and requires 0.15-0.7 MPa to unlock.
When ordering a replacement, match the 80 mm bore, 125 mm stroke, PT3/8 cylinder port, and desired mounting option. SE-compatible mounting accessories fit this cylinder except FTC. Because the stroke is 125 mm, ensure adequate guide support to prevent side-load wear on the rod and collet.
Quick checklist
The lock is spring-applied and air-released, making it fail-safe. If air is lost, exhausted, or an E-stop trips, the collet clamps the rod and holds the load in both directions with a static holding force of 3600 N.
The drive force is 2513 N push and 2268 N pull at 0.5 MPa, and 3518 N push at 0.7 MPa (max 359 kgf drive). This is separate from the 3600 N static holding force. To release, apply 0.15-0.7 MPa to the G1/8 port only after the piston is stopped and pressures are balanced, allowing at least 0.5 seconds before moving.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.