The AirTAC Airtac BSE Clamp Standard Cylinder BSE80X450S is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø25mm rod and holds up to 3600 N in either direction — no drift. Ø80mm bore, 450mm stroke, PT3/8 cylinder ports, G1/8 lock-release port.
The AirTAC BSE80X450S is a double-acting ISO 15552 profile cylinder with an integrated spring-applied, air-released rod lock. It delivers a 3600 N bidirectional static holding force, ensuring suspended loads remain safely frozen in place if air pressure drops or an E-stop is hit. Operating pressure is capped at 0.7 MPa, and the lock utilizes a separate G1/8 release port.
This 80 mm bore, 450 mm stroke unit features a 25 mm rod and adjustable air cushions at both ends. The integrated collet lock is a holding device, not a dynamic brake; it must only engage after the rod fully stops. The -S magnet option supports CMSE reed and DMSE electronic sensors for precise position tracking.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE80X450S holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE80X450S |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø80 mm |
| Stroke | 450 mm |
| Static holding force | 3600 N |
| Cylinder port | PT3/8 |
| Lock-release port | G1/8 |
| Rod thread | M20×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 36 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa (max) | 3519 N | — |
| Max drive (@0.7 MPa) | 359 kgf | |
Drive force is separate from the 3600 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 80 | Bore size in mm. |
| ×450 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds heavy mold platens mid-stroke. The 3600 N collet lock prevents sudden drops if factory air supply drops, while the 2513 N drive force moves the tooling.
Secures vertical lift arms carrying pallets. The fail-safe spring-applied lock engages instantly on E-stop, preventing gravity-driven falls without live air.
Locks large package diverter gates in the extended position. The bidirectional hold ensures the gate stays put against impacting cartons during line jams.
Verify your load requires a holding force at or below 3600 N. If you need less holding or drive force, the adjacent 63 mm bore offers 1559 N push at 0.5 MPa and a 2200 N hold. If your load is higher, stepping up to the 100 mm bore provides 3927 N push at 0.5 MPa and a 5500 N hold. The drive force for this 80 mm bore is 2513 N push and 2268 N pull at 0.5 MPa.
At 450 mm stroke, use guide rails to prevent side-load wear on the seals. To replace this unit, match the 80 mm bore, 450 mm stroke, PT3/8 port, and -S magnet. SE mounting accessories fit this body directly, except FTC brackets. Always balance pressures on both sides of the piston and allow at least 0.5 s for full lock release before moving.
Quick checklist
The drive force is 2513 N push and 2268 N pull at 0.5 MPa, and 3518 N push at 0.7 MPa (max 359 kgf). The separate static holding force of the rod lock is 3600 N, which holds the load with no live air.
A spring applies a clamping collet to the rod, so air loss instantly engages the 3600 N bidirectional hold. To release, supply 0.15-0.7 MPa to the G1/8 release port, ensure both piston sides are pressure-balanced, and wait at least 0.5 s before moving.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.