The AirTAC Airtac BSE Clamp Standard Cylinder BSE40X75S is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø16mm rod and holds up to 900 N in either direction — no drift. Ø40mm bore, 75mm stroke, PT1/4 cylinder ports, G1/8 lock-release port.
The AirTAC BSE40X75S is a 40mm bore, 75mm stroke ISO 15552 profile cylinder featuring an integrated spring-applied, air-released rod lock. It delivers a bidirectional static holding force of 900 N with no live air required, ensuring suspended loads remain safely locked during pressure loss or E-stop events. Operating pressure is capped at 0.7 MPa.
This double-acting single-rod actuator features a separate G1/8 release port to disengage the clamping collet. The lock is a fail-safe holding device, not a dynamic brake; it must be engaged only after the rod stops and released only when piston pressures are balanced, allowing at least 0.5 seconds for full release before motion. The -S magnet option enables position sensing with CMSE reed or DMSE electronic sensors.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE40X75S holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE40X75S |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø40 mm |
| Stroke | 75 mm |
| Static holding force | 900 N |
| Cylinder port | PT1/4 |
| Lock-release port | G1/8 |
| Rod thread | M12×1.25 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 30 mm |
| Max stroke | Up to 800 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa (max) | 880 N | — |
| Max drive (@0.7 MPa) | 90 kgf | |
Drive force is separate from the 900 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 40 | Bore size in mm. |
| ×75 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a mid-stroke vertical lifting stage securely in place with 900 N of fail-safe force, preventing gravity drops if the air supply drops below 0.15 MPa.
Maintains clamping pressure on machined parts during an E-stop, keeping the 879 N drive force locked out until pressures balance and the G1/8 port releases the collet.
Acts as a rigid stop gate for lightweight conveyor pallets, using the spring-applied collet to stay firmly positioned without consuming continuous air.
Verify your load does not exceed the 900 N static holding force. If stepping down, the 32mm bore offers 402 N push at 0.5 MPa and a 600 N hold. If stepping up, the 50mm bore provides 982 N push at 0.5 MPa and a 1400 N hold. Always engage the lock only after the rod completely stops, and release it solely when pressures are balanced, allowing >=0.5 s before moving.
To match this actuator exactly, specify the 40mm bore, 75mm stroke, PT1/4 cylinder port, and the -S magnet option. SE-compatible mounting accessories fit this body perfectly, except for the FTC model. Because the 75mm stroke is under 300mm, external side-load guides are less critical here than on longer strokes, but always ensure axial load alignment.
Quick checklist
The spring-applied collet engages automatically to provide a 900 N static holding force in both directions if air is lost. The drive forces are 628 N push and 528 N pull at 0.5 MPa, 879 N push at 0.7 MPa, with a max drive of 90 kgf.
You must balance the air pressures on both sides of the piston first. Then supply 0.15-0.7 MPa to the separate G1/8 release port, wait at least 0.5 seconds for the collet to fully retract, and only then command cylinder motion.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.