The AirTAC Airtac BSE Clamp Standard Cylinder BSE50X100S is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø20mm rod and holds up to 1400 N in either direction — no drift. Ø50mm bore, 100mm stroke, PT1/4 cylinder ports, G1/8 lock-release port.
The AirTAC BSE50X100S is a double-acting ISO 15552 profile cylinder with an integrated spring-applied, air-released rod lock. It provides a bidirectional fail-safe holding force of 1400 N, clamping the Ø20 mm rod via collet to prevent drift when air is exhausted or E-stop is engaged. Operating pressure is capped at 0.7 MPa.
This 50 mm bore unit delivers a drive force of 982 N push and 825 N pull at 0.5 MPa, reaching 1374 N push at 0.7 MPa. The lock uses a separate G1/8 release port and requires 0.5 s for full unlock after pressures balance. The -S option includes a magnet for CMSE reed or DMSE electronic sensors.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE50X100S holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE50X100S |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø50 mm |
| Stroke | 100 mm |
| Static holding force | 1400 N |
| Cylinder port | PT1/4 |
| Lock-release port | G1/8 |
| Rod thread | M16×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 30 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa (max) | 1374 N | — |
| Max drive (@0.7 MPa) | 140 kgf | |
Drive force is separate from the 1400 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 50 | Bore size in mm. |
| ×100 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds suspended packaging machine elevators mid-stroke, preventing a 1400 N load from dropping under air loss while delivering 982 N push at 0.5 MPa.
Secures machining clamps in position during an E-stop, using the collet lock to maintain the hold without live air while the drive provides 825 N pull.
Locks a conveyor diverter gate rigidly in place, using the 1400 N static hold to resist impact from pallets while the cylinder cycles at 30-800 mm/s.
Verify your load requires holding force under the 1400 N capacity. If you need less drive force, the 40 mm bore offers 628 N push at 0.5 MPa and 900 N hold; if you need more, the 63 mm bore provides 1559 N push at 0.5 MPa and 2200 N hold. Engage the lock only after the rod fully stops, and release it only when piston pressures are balanced.
For replacement matching, confirm the 100 mm stroke, PT1/4 cylinder port, and M16x1.5 rod thread. SE mounting accessories fit this body except FTC. Because stroke is under 300 mm, standard side-load risks are minimal, but always guide external heavy loads.
Quick checklist
The spring-applied collet clamps the rod instantly upon air loss, delivering a 1400 N static hold in both directions. Drive forces are 982 N push and 825 N pull at 0.5 MPa, 1374 N push at 0.7 MPa, with a max drive of 140 kgf.
You must balance pressures on both sides of the piston first. Then supply 0.15-0.7 MPa to the separate G1/8 release port to free the collet, allowing at least 0.5 seconds before commanding movement.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.