The AirTAC Airtac BSE Clamp Standard Cylinder BSE50X500S is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø20mm rod and holds up to 1400 N in either direction — no drift. Ø50mm bore, 500mm stroke, PT1/4 cylinder ports, G1/8 lock-release port.
The AirTAC BSE50X500S is a double-acting ISO 15552 profile cylinder featuring an integrated spring-applied, air-released rod lock. It delivers a fail-safe bidirectional holding force of 1400 N. If air pressure drops or an E-stop trips, the collet clamps the piston rod instantly, holding the load securely in place without live air.
Operating pressure is capped at 0.7 MPa, and unlocking requires 0.15-0.7 MPa supplied to the separate G1/8 release port. This 50 mm bore unit includes a magnet for position sensing and provides drive forces of 982 N push and 825 N pull at 0.5 MPa. The 500 mm stroke requires external guide support to prevent side-load damage to the seal and rod.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE50X500S holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE50X500S |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø50 mm |
| Stroke | 500 mm |
| Static holding force | 1400 N |
| Cylinder port | PT1/4 |
| Lock-release port | G1/8 |
| Rod thread | M16×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 30 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa (max) | 1374 N | — |
| Max drive (@0.7 MPa) | 140 kgf | |
Drive force is separate from the 1400 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 50 | Bore size in mm. |
| ×500 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a raised pallet stack stationary during air loss. The 1400 N collet lock prevents drifting down, while the 982 N drive force easily lifts the load.
Secures a 500 mm extended tool head safely in place during an E-stop. The fail-safe lock engages instantly, preventing unintended descent.
Maintains a raised stop position on a conveyor line when air is exhausted. The lock sustains the 1400 N holding force without consuming live air.
Verify your load requires 1400 N or less of static holding force. If you need less holding and drive force, step down to the 40 mm bore, which offers 628 N push at 0.5 MPa and 900 N hold. If your load exceeds 1400 N, step up to the 63 mm bore, providing 1559 N push at 0.5 MPa and 2200 N hold.
Always engage the lock only after the rod has completely stopped, and release it only when pressures on both sides of the piston are balanced, allowing at least 0.5 s for full release. For a direct replacement, match the 50 mm bore, 500 mm stroke, PT1/4 port, and -S magnet option. Because the stroke is 500 mm, use external guides to manage side loads. SE mounting accessories fit this body, except FTC.
Quick checklist
On air loss, the spring-applied collet clamps the rod, providing a 1400 N bidirectional fail-safe hold. The drive forces are 982 N push and 825 N pull at 0.5 MPa, 1374 N push at 0.7 MPa, and a max drive of 140 kgf.
Ensure the cylinder rod has completely stopped moving and the pressures on both sides of the piston are balanced. Then supply 0.15-0.7 MPa to the G1/8 release port, allowing at least 0.5 s for full release before resuming motion.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.