The AirTAC Airtac BSE Clamp Standard Cylinder BSE80X225S is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø25mm rod and holds up to 3600 N in either direction — no drift. Ø80mm bore, 225mm stroke, PT3/8 cylinder ports, G1/8 lock-release port.
The AirTAC BSE80X225S is a double-acting ISO 15552 profile cylinder with an integrated spring-applied, air-released rod lock. A collet clamps the 25 mm rod, delivering a 3600 N bidirectional static holding force with zero live air. Operating pressure is capped at 0.7 MPa, and the lock uses a separate G1/8 release port.
This fail-safe mechanism prevents drift on suspended loads during air loss or E-stops. The lock is a holding device, not a dynamic brake. You must engage it only after the rod stops, and release it only when piston pressures are balanced, allowing at least 0.5 s for full release. The -S option includes a magnet for CMSE and DMSE sensors.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE80X225S holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE80X225S |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø80 mm |
| Stroke | 225 mm |
| Static holding force | 3600 N |
| Cylinder port | PT3/8 |
| Lock-release port | G1/8 |
| Rod thread | M20×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 36 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa (max) | 3519 N | — |
| Max drive (@0.7 MPa) | 359 kgf | |
Drive force is separate from the 3600 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 80 | Bore size in mm. |
| ×225 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Secures a 300 kg vertical spindle during an air pressure drop. The 3600 N collet lock holds the load safely, preventing a crash while the 3518 N drive handles the cutting feed.
Maintains clamping force on a stamping die if an E-stop trips. The fail-safe collet engages instantly, holding the tool steady without needing continuous 0.7 MPa air.
Locks a heavy routing gate in the extended position across a packaging line. The spring-applied lock resists conveyor vibration and holds the 25 mm rod firmly during line jams.
Verify your load stays under the 3600 N holding force. If you need less holding or drive force, the 63 mm bore offers 1559 N push at 0.5 MPa and 2200 N hold. If you need more, the 100 mm bore gives 3927 N push at 0.5 MPa and 5500 N hold. Drive force here is 2513 N push and 2268 N pull at 0.5 MPa, peaking at 359 kgf at 0.7 MPa.
For this 225 mm stroke, side-load is moderate, but always guide the load to protect the rod seal. When replacing a unit, match the 80 mm bore, 225 mm stroke, PT3/8 cylinder port, and mounting. SE mounting accessories fit this body, except FTC brackets.
Quick checklist
The lock is spring-applied and air-released. If air is lost or exhausted, a collet clamps the 25 mm rod, providing a 3600 N bidirectional static hold. It is a fail-safe holding device, not a dynamic brake, so engage it only after the rod stops.
Drive force at 0.5 MPa is 2513 N push and 2268 N pull, peaking at 359 kgf at 0.7 MPa. The static holding force is 3600 N. To release the lock, supply air to the G1/8 port, ensure piston pressures are balanced, and wait at least 0.5 s before moving.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.