The AirTAC Airtac BSE Clamp Standard Cylinder BSE80X600S is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø25mm rod and holds up to 3600 N in either direction — no drift. Ø80mm bore, 600mm stroke, PT3/8 cylinder ports, G1/8 lock-release port.
The AirTAC BSE80X600S is a double-acting, single-rod ISO 15552 profile cylinder equipped with an integrated spring-applied, air-released rod lock. It features a 600 mm stroke and a 25 mm rod with an M20x1.5 thread. The cylinder operates at 0.15-0.7 MPa, utilizing a PT3/8 port for drive air and a separate G1/8 port for lock release.
This fail-safe collet mechanism provides a 3600 N bidirectional static holding force without consuming live air. Because the lock engages automatically upon air loss or E-stop activation, it secures the load precisely where it stopped. Remember to engage the lock only after the rod stops moving and allow at least 0.5 s for full release before resuming motion.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE80X600S holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE80X600S |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø80 mm |
| Stroke | 600 mm |
| Static holding force | 3600 N |
| Cylinder port | PT3/8 |
| Lock-release port | G1/8 |
| Rod thread | M20×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 36 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa (max) | 3519 N | — |
| Max drive (@0.7 MPa) | 359 kgf | |
Drive force is separate from the 3600 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 80 | Bore size in mm. |
| ×600 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a 360 kg vertical lifting carriage firmly in place during an E-stop, preventing gravity-driven drops without needing continuous air supply.
Secures a 600 mm stroke diverter arm in the extended position on a sorting line, using 2513 N of push force at 0.5 MPa to move heavy cartons.
Locks suspended machining tooling at full extension, relying on the spring-applied collet to keep the 25 mm rod immobile if the main air line exhausts.
Verify your suspended load requires 3600 N or less of holding force. If your application needs less drive, the 63 mm bore offers 1559 N push at 0.5 MPa and a 2200 N hold. If you need more stopping security, the 100 mm bore provides 3927 N push at 0.5 MPa and a 5500 N hold. Both alternatives maintain the 0.7 MPa operating ceiling.
With a 600 mm stroke, you must account for side-load risks; use external guide rails to prevent rod bending and premature seal wear. When ordering a replacement, match the 80 mm bore, 600 mm stroke, PT3/8 thread, and the -S magnet option. SE mounting accessories fit this body perfectly, except for the FTC variant.
Quick checklist
At 0.5 MPa, the drive push force is 2513 N and the pull force is 2268 N. At the maximum operating pressure of 0.7 MPa, the push force is 3518 N (max 359 kgf). The static holding force of the spring-applied rod lock is 3600 N, which is separate from the pneumatic drive force.
The lock is spring-applied and air-released, meaning a loss of air pressure causes the collet to clamp the rod instantly, providing a 3600 N bidirectional hold. It is not a dynamic brake; you must engage it only after the rod stops, balance pressures on both sides, and allow 0.5 s for release before moving.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.