The AirTAC Airtac BSE Clamp Standard Cylinder BSE100X300 is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø25mm rod and holds up to 5500 N in either direction — no drift. Ø100mm bore, 300mm stroke, PT1/2 cylinder ports, G1/8 lock-release port.
The AirTAC BSE100X300 is a double-acting, single-rod ISO 15552 profile cylinder featuring an integrated spring-applied, air-released rod lock. It provides a robust 5500 N static holding force, securing suspended loads in both directions the moment air pressure is lost or an E-stop is triggered. Operating pressure is capped at 0.7 MPa, and the lock unlocks via a dedicated G1/8 port.
This 100mm bore actuator generates 5497 N of drive force at 0.7 MPa while extending up to a 300mm stroke. The lock is a static collet clamp, not a dynamic brake; it must only engage after the rod fully stops. Because this specific SKU lacks a magnet (-S), it cannot host CMSE or DMSE position sensors.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE100X300 holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE100X300 |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø100 mm |
| Stroke | 300 mm |
| Static holding force | 5500 N |
| Cylinder port | PT1/2 |
| Lock-release port | G1/8 |
| Rod thread | M20×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 36 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa (max) | 5498 N | — |
| Max drive (@0.7 MPa) | 561 kgf | |
Drive force is separate from the 5500 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 100 | Bore size in mm. |
| ×300 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds heavy stamping tooling at 300mm extension. The 5500 N collet lock prevents the 100mm rod from drifting downward if shop air suddenly exhausts.
Secures a vertical lift stage mid-travel. The spring-applied lock engages instantly on air loss, safely suspending the load without needing live pressure.
Acts as a hard stop for heavy pallets on a conveyor. The fail-safe collet ensures the 300mm extended gate remains rigidly locked during emergency power-offs.
Verify your load stays within the 5500 N holding capacity and the 5497 N push force at 0.7 MPa. If your load is lighter, the 80mm bore offers 3518 N push and 3600 N hold; for heavier demands, the 125mm bore provides 8590 N push and 8600 N hold. Always balance pressures on both sides of the piston before releasing the lock, allowing at least 0.5 seconds for full release.
At 300mm stroke, prevent rod side-loading by guiding the load externally. This unit uses a PT1/2 cylinder port and a PT thread form. You can reuse SE-compatible mounting accessories (except FTC) to fit your ISO 15552 interface.
Quick checklist
The drive force at 0.5 MPa is 3927 N push and 3681 N pull; at 0.7 MPa, push is 5497 N (max drive 561 kgf). The separate static rod-lock provides a 5500 N bidirectional holding force with no live air.
The lock is spring-applied and air-released via a G1/8 port. You must first balance pressures on both sides of the piston, then supply 0.15-0.7 MPa to the release port, allowing at least 0.5 seconds before moving the rod.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.