The AirTAC Airtac BSE Clamp Standard Cylinder BSE100X700S is a genuine double-acting ISO 15552 cylinder with an integrated spring-applied, air-released ROD LOCK. If air is cut or an E-stop is hit, the collet clamps the Ø25mm rod and holds up to 5500 N in either direction — no drift. Ø100mm bore, 700mm stroke, PT1/2 cylinder ports, G1/8 lock-release port.
The AirTAC BSE100X700S is a double-acting ISO 15552 profile cylinder with an integrated spring-applied, air-released rod lock. It delivers a 5500 N bidirectional static holding force with no live air, ensuring suspended loads stay exactly where they stopped during an E-stop or pressure drop. The operating pressure ceiling is 0.15-0.7 MPa.
This 100mm bore, 700mm stroke unit uses a separate G1/8 release port to unlock the internal collet. The lock is a holding device, not a dynamic brake; you must engage it only after the rod stops and release it only when piston pressures are balanced, allowing at least 0.5 seconds before moving. The -S magnet supports CMSE reed and DMSE electronic sensors.
A spring clamps the collet onto the rod, so the Airtac BSE Clamp Standard Cylinder BSE100X700S holds its position in both directions when air is lost, exhausted or an E-stop trips. Apply 0.15–0.7 MPa to the G1/8 release port to unlock. Engage the lock only after the rod has stopped (it is not a dynamic brake), and release only when the pressures on both sides of the piston are balanced. Allow at least 0.5 s for full release before moving.
| Model | Airtac BSE Clamp Standard Cylinder BSE100X700S |
|---|---|
| Series | BSE ISO 15552 rod-lock cylinder |
| Bore size | Ø100 mm |
| Stroke | 700 mm |
| Static holding force | 5500 N |
| Cylinder port | PT1/2 |
| Lock-release port | G1/8 |
| Rod thread | M20×1.5 |
|---|---|
| Operating pressure | 0.15 – 0.7 MPa |
| Unlocking pressure | 0.15 – 0.7 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 36 mm |
| Max stroke | Up to 1000 mm |
Specifications follow the official AirTAC BSE datasheet. The lock uses the SE standard body; SE mounting accessories fit BSE except FTC. Port options: PT (standard) / G (BSPP); lock-release port is G1/8.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa (max) | 5498 N | — |
| Max drive (@0.7 MPa) | 561 kgf | |
Drive force is separate from the 5500 N static holding force of the lock. BSE operates up to 0.7 MPa. Size with a safety margin.
| B | Rod-lock cylinder prefix. |
|---|---|
| SE | ISO 15552 standard double-acting body. |
| 100 | Bore size in mm. |
| ×700 | Stroke length in mm. |
| -S | Optional built-in magnet for CMSE / DMSE sensor sensing. |
Thread: PT (blank) / G. Mounting (BSE): Basic, LB, FA, FB, CA, CB, CR, TC (FTC is not available on BSE). Related: SE (no lock), BSED (double-rod rod lock). Sensors CMSE/DMSE fit magnetic BSE.
Holds a lifted pallet arm safely mid-stroke. The 5500 N collet lock prevents a 561 kgf drive load from crashing down if the main air supply drops unexpectedly.
Secures heavy mold halves during a machine halt. The fail-safe collet engages instantly on air loss, keeping the 100mm rod clamped until balance is restored.
Maintains a raised stop gate on a high-speed packaging line. The spring-applied lock keeps the gate up during E-stops, blocking 5497 N of push force without live air.
Verify your suspended load is safely under the 5500 N static holding limit. If your load is lighter, stepping down to the 80mm bore offers 2513 N push at 0.5 MPa and a 3600 N hold. If you need more drive force, the 125mm bore provides 6136 N push at 0.5 MPa and an 8600 N hold. Always engage the lock only after the rod fully stops, and release it only when both sides are pressure-balanced.
For a direct replacement, match the 100mm bore, 700mm stroke, PT1/2 cylinder port, and -S magnet. Because the 700mm stroke is long, use external guides to prevent side-load wear on the seals. SE mounting accessories fit this ISO 15552 body perfectly, except for the FTC variant.
Quick checklist
The drive force is 3927 N push and 3681 N pull at 0.5 MPa, 5497 N push at 0.7 MPa, and a maximum of 561 kgf at 0.7 MPa. The separate static holding force of the spring-applied rod lock is 5500 N.
On air loss, the internal spring instantly forces a collet to clamp the rod, providing a 5500 N bidirectional hold. To release it safely, balance pressures on both sides of the piston, supply 0.15-0.7 MPa to the G1/8 release port, and wait at least 0.5 seconds before moving.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.