Genuine AirTAC valve manifold, order code 200M-10F from the 4AM range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The AirTAC 200M manifold base joins several 4A200 air-piloted valves into one bank with a shared air supply and exhaust, cutting piping work and making faults easier to trace. This 10-station version carries ten valves side by side behind a PT-threaded supply, and the assembled length A works out to 251 mm: 44 mm for the first station plus 23 mm for each of the nine added stations.
AirTAC ships the manifold together with its seals and screws, so the valves bolt straight onto the base. Any station left without a valve is closed off with the separate blank plate kit P-200M-R2. Supply air should be filtered to 40 um, and the manifold operates from -20 to +70 C.
| Order code | 200M-10F |
|---|---|
| Product | Valve Manifold |
| Manifold | 200M (for 4A200) |
| Stations | 10 stations |
| Thread | PT |
| Models | 100M / 200M / 300M / 400M |
|---|---|
| For valves | 4A100 / 4A200 / 4A300 / 4A400 |
| Maximum stations | 16 / 16 / 12 / 8 |
| Supply port P | 1/4" / 1/4" / 3/8" / 1/2" |
| Length A | 100M 38 + 19 × (n-1) mm; 200M 44 + 23 × (n-1) mm; 300M 52 + 28 × (n-1) mm; 400M 61 + 35 × (n-1) mm |
| Fluid | Air, filtered to 40 µm |
| Temperature | -20 to +70 °C |
| Included | Manifold, seals and screws |
| Blank plate | Kit P-□00M-R2 (separate) |
Source: AirTAC 4A manifold datasheet (p.124), ordering code, specifications and dimensions.
200M is sized for the 4A200 valve series; 100M (for 4A100) and 300M (for 4A300) will not mount these valves. Within the 200M family, 9F and 11F sit one station either side of this 10F build, and each extra station adds 23 mm of length. PT thread is the default ending, so order G or T only if your piping is G or NPT.
One PT feed at port P supplies ten 4A200 valves that drive the pusher and gate cylinders along a conveyor line, all traceable at a single bank.
Group the clamp, seal and eject valves of a carton packer on a 251 mm long 200M base instead of plumbing ten individual valve bodies.
Ten 4A200 stations in one assembly keep the pneumatic wiring of an automation cabinet tidy, with a 1/4 inch supply port and a shared exhaust.
It accepts ten 4A200 valves, one per station, on a PT-threaded supply with a 1/4 inch port P. Overall length A is 251 mm, from a 44 mm base plus 23 mm per added station. The package includes the manifold, seals and screws; spare stations are closed with the P-200M-R2 blank plate kit.
The fluid is air filtered to 40 um, and the operating temperature range is -20 to +70 C. Keep within these limits so the included seals and the mounted 4A200 valves actuate reliably.