Genuine AirTAC valve manifold, order code 200M-12F from the 4AM range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
Twelve 4A200 air-piloted valves share one air supply and one exhaust on this AirTAC 200M bank, replacing a dozen individual connections with a single 1/4 inch PT feed at port P. At twelve stations the assembly measures 297 mm along length A (44 mm for the first station, 23 mm for each of the eleven added), a footprint that still sits inside the 200M series' 16-station ceiling.
AirTAC supplies the manifold complete with seals and screws; stations you do not fill are closed with the separate P-200M-R2 blank plate kit. Run air filtered to 40 um and keep the ambient between -20 and +70 C for reliable sealing and valve actuation.
| Order code | 200M-12F |
|---|---|
| Product | Valve Manifold |
| Manifold | 200M (for 4A200) |
| Stations | 12 stations |
| Thread | PT |
| Models | 100M / 200M / 300M / 400M |
|---|---|
| For valves | 4A100 / 4A200 / 4A300 / 4A400 |
| Maximum stations | 16 / 16 / 12 / 8 |
| Supply port P | 1/4" / 1/4" / 3/8" / 1/2" |
| Length A | 100M 38 + 19 × (n-1) mm; 200M 44 + 23 × (n-1) mm; 300M 52 + 28 × (n-1) mm; 400M 61 + 35 × (n-1) mm |
| Fluid | Air, filtered to 40 µm |
| Temperature | -20 to +70 °C |
| Included | Manifold, seals and screws |
| Blank plate | Kit P-□00M-R2 (separate) |
Source: AirTAC 4A manifold datasheet (p.124), ordering code, specifications and dimensions.
This 12F build is the 200M manifold for 4A200 valves in PT thread; the bank grows by 23 mm per station, so 200M-11F saves 23 mm and 200M-13F adds a thirteenth valve. Larger 4A300 valves need the 300M series, which tops out at 12 stations, while 4A100 valves mount on 100M bases. End the code in G or T for G or NPT threads instead of PT.
Twelve 4A200 outputs from one 297 mm base can feed the grippers, clamps and kickers of a dedicated automation cell through a single PT supply.
Mount twelve valves behind one panel plate and wire trace faults at one bank rather than chasing twelve separately plumbed 4A200 bodies.
Group the eject, clamp and flap cylinders of a packaging conveyor onto one 1/4 inch supplied manifold with a shared exhaust path.
For 4A200 valves, twelve stations, PT thread, supply port P 1/4 inch, length A 297 mm (44 mm base plus 23 mm per added station), fluid air filtered to 40 um, temperature -20 to +70 C, maximum 200M bank size 16 stations. Manifold, seals and screws are included; blank stations use the P-200M-R2 kit.
Yes. The 200M series accepts up to 16 stations, so a thirteenth valve can be added with a longer order code, and any unfilled station on this 12F base is closed with the separate P-200M-R2 blank plate kit. Mounting seals and screws already come with the manifold.