Genuine AirTAC valve manifold, order code 200M-15F from the 4AM range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
This 200M manifold arranges fifteen 4A200 valves in one bank with a common supply and exhaust, trimming pipe runs and keeping faults easy to trace on the machine. Because the code ends without a G or T letter, the ports are PT thread.
Fifteen stations produce a body length A of 44 mm plus 23 mm for each of the fourteen extra stations, giving 366 mm. The 1/4 inch supply port P serves the whole bank; the fluid is air filtered to 40 um and the temperature range is -20 to +70 C. The order contains the manifold, seals and screws, while stations left open are closed with the separately ordered P-200M-R2 blank plate kit.
| Order code | 200M-15F |
|---|---|
| Product | Valve Manifold |
| Manifold | 200M (for 4A200) |
| Stations | 15 stations |
| Thread | PT |
| Models | 100M / 200M / 300M / 400M |
|---|---|
| For valves | 4A100 / 4A200 / 4A300 / 4A400 |
| Maximum stations | 16 / 16 / 12 / 8 |
| Supply port P | 1/4" / 1/4" / 3/8" / 1/2" |
| Length A | 100M 38 + 19 × (n-1) mm; 200M 44 + 23 × (n-1) mm; 300M 52 + 28 × (n-1) mm; 400M 61 + 35 × (n-1) mm |
| Fluid | Air, filtered to 40 µm |
| Temperature | -20 to +70 °C |
| Included | Manifold, seals and screws |
| Blank plate | Kit P-□00M-R2 (separate) |
Source: AirTAC 4A manifold datasheet (p.124), ordering code, specifications and dimensions.
Choose 200M-15F when fifteen 4A200 valves, or fewer closed with blank plates, share one bank; its neighbours are 200M-14F and the 16-station ceiling code 200M-16F, the last option before the 200M maximum is reached. The 23 mm per-station pitch suits 4A200 bodies; if your valves are 4A300, step to a 300M bank with its 28 mm pitch and 3/8 inch supply port, or to 400M for 4A400 at a 35 mm pitch.
Consolidate the valves for clamping, air blow-off and part ejection at fifteen positions behind one 1/4 inch supply port.
Coordinate pushers and hold-downs across fifteen stations of a feed line, vented through one shared exhaust.
Drive fifteen pick-and-place helper cylinders from a single bank that spans 366 mm along the cell frame.
Fifteen stations for 4A200 valves, PT thread (the code carries no G or T), 1/4 inch supply port P, length A of 366 mm (44 mm plus 23 mm per extra station), 16-station maximum for the 200M series, air filtered to 40 um, and -20 to +70 C.
Add one 4A200 valve per active station; the order itself brings the manifold, seals and screws. Any station kept without a valve is closed with the P-200M-R2 blank plate kit ordered separately, and a thread letter G or T only applies if you need non-PT ports.