The AirTAC 3V200M-15 3V-F Base (3V200M15F) is a genuine 3V-F manifold base manifold base for 15 stations on one shared air supply. A base is a machined block: it carries no coil and no solenoid, so the valves that sit on it are ordered separately.
The 3V200M15F is a fifteen-station manifold base in the AirTAC 3V200M family. It is a machined block that lets you mount fifteen 3/2 solenoid valves side by side on a single shared air supply, so fifteen switching points in a machine can be fed from one supply line instead of fifteen separate drops. The base itself carries no coil and no wiring logic of its own: it is the common air gallery and the mounting interface.
We stock this base as a genuine AirTAC part, and the valves that sit on it are ordered separately, which means you can mix normally closed and normally open stations, different coil voltages and different electrical entries on one block as your panel requires. We hold both NC and NO valves, all five standard coil voltages and both DIN plug and flying-lead entries across this family. Any performance figure you need for the valves will be confirmed from the datasheet on request.
| Model | AirTAC 3V200M-15 3V-F Base (3V200M15F) |
|---|---|
| Series | 3V-F manifold base |
| Item form | Manifold base (no coil, no solenoid, no initial state) |
| Stations | 15 |
| Port size | Confirm from the datasheet — ask us |
| Thread | PT |
| Operating pressure | Confirm from the datasheet — ask us |
|---|---|
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V-F manifold base | Body. |
|---|---|
| 15F | 15 stations in one assembly. |
| PT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A palletiser with fifteen single-acting clamp or pusher stations can share one air gallery: this base carries the whole clamp group, and each spring-return clamp gets its own 3/2 valve station on the block.
On a filling or wrapping line where a row of nozzles is pulsed to clear product or dust from trays, one manifold supplies all the on/off air points, cutting pipework across the frame to a single feed.
In a control cabinet or on a machine subplate, mounting the 3/2 valve set on one base puts every indicator, coil and connection in one place, which shortens the wiring loom and speeds up station-by-station diagnosis.
A manifold base earns its place when a machine has many 3/2 switching points in one area: one air feed and one wiring loom replace a nest of individual valves, and fault-finding gets simpler because every station sits in one visible row. At fifteen stations this is the right choice for a densely packed machine rather than a small retrofit. Remember that the valves are a separate line item, so order fifteen valves plus this base, and match each coil voltage to its own control circuit. Because we do not hold published flow figures for this family in-house, send us the actuators each station will drive and we will confirm sizing from the datasheet before you order. If you need a 3-port valve with fully published figures today, the documented 3V2 and 3V3 direct-acting bodies carry their own flow and coil-power data. And if any of your stations drives a double-acting cylinder, that station needs a 5-port valve from the AirTAC 4V series instead - a 3/2 valve cannot switch it.
Confirm before you order
The base itself is a machined block with a stated station count and thread; it has no coil, pressure setting or flow path of its own. The specifications that matter - pressure range, flow and coil power - belong to the valves you mount on it. Send us your station list and we will confirm those figures from the datasheet on request. If you need a 3-port valve with published flow and coil-power figures available immediately, the documented AirTAC 3V2 and 3V3 direct-acting bodies are the alternative to check first.
No - valves are ordered separately, so a fifteen-station build is this base plus fifteen 3/2 valves. Each station suits a single-acting (spring-return) cylinder, an on/off air or blow duty, or piloting a larger valve. A 3/2 valve cannot drive a double-acting cylinder, which needs both a feed and an exhaust in each direction; for those actuators use a 5-port valve from the AirTAC 4V series on a compatible manifold instead.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity and destination. We confirm price, availability and lead time — usually within 7 hours.