The AirTAC 3V-F Base 3V200M5F is a genuine 3V-F manifold base manifold base for 5 stations on one shared air supply. A base is a machined block: it carries no coil and no solenoid, so the valves that sit on it are ordered separately.
The 3V200M5F is a five-station manifold base for AirTAC 3/2 solenoid valves. A 3/2 valve has three ports - supply, outlet and exhaust - and two states: it either feeds air to the outlet or vents it to exhaust, which is what single-acting cylinders, air blow and clamp circuits need. A manifold base sits underneath several of these valves at once, giving them one common air feed, so instead of plumbing five separate supply lines you machine one connection and the base distributes it.
We stock the 3V200M5F as a genuine AirTAC part and ship it with PT thread as standard. The base itself carries no coil, so it has no voltage, no electrical state and no power draw - those belong to the valves you bolt on top, and they are ordered separately. Across the matching family we can supply normally closed and normally open valves, all five coil voltages, DIN plug and flying-lead entries, and bases from single-station up to twenty. Any datasheet figure you need for the valves you intend to mount, ask us with your RFQ and we will confirm it from the datasheet before you order.
| Model | Airtac 3V-F Base 3V200M5F |
|---|---|
| Series | 3V-F manifold base |
| Item form | Manifold base (no coil, no solenoid, no initial state) |
| Stations | 5 |
| Port size | Confirm from the datasheet — ask us |
| Thread | PT |
| Operating pressure | Confirm from the datasheet — ask us |
|---|---|
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V-F manifold base | Body. |
|---|---|
| 5F | 5 stations in one assembly. |
| PT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Five single-acting swing clamps or edge clamps on a jig, each fed and vented by its own 3/2 valve on one manifold. The shared supply keeps the fixture plumbed once, and a failed clamp station can be swapped without disturbing the other four.
On a cartoning or filling line, several short air blasts - pushing a rejected pack off the belt, clearing crumbs from a sealing jaw - run from individual 3/2 valves. A manifold base consolidates their supplies and lets the electrician land all coils in one wiring loom.
A workstation where an operator cycles a press cylinder, an air blow gun circuit and small clamps in sequence. Each function gets its own valve position, so a logic change at one station never means re-plumbing the whole bench.
Plan the base and the valves as one decision. Five stations means five valve positions on one shared supply, so order one valve per station and choose each one by its circuit: normally closed where the outlet must stay dead on power loss, normally open where it must stay live. Match each coil to your panel voltage - it is fixed at order time, not changed by rewiring - and pick DIN plug or flying-lead entry per position to suit your wiring loom. A manifold like this pays for itself on multi-clamp fixtures: one air feed, one wiring run, and a fault you can isolate station by station.
One caution on sizing: we do not hold published flow figures for this family, so ask us to check the valves against your actuators before you commit. If you need a 3-port valve with full published flow and coil-power data today, the AirTAC 3V2 and 3V3 bodies are documented alternatives we stock. If your circuit needs a double-acting cylinder, that takes a 5-port valve - go to the AirTAC 4V series instead.
Confirm before you order
The base itself is a machined block with no electrical or pressure ratings of its own. For the valves, send us your RFQ and we will confirm the pressure range, flow, coil power and other figures from the datasheet on request. If you need those numbers published before you buy, the AirTAC 3V2 and 3V3 bodies carry documented specifications and are stocked as well.
Valves are ordered separately - the base carries five positions and you fill each with a 3/2 valve in your choice of NC or NO, coil voltage and electrical entry. Those valves suit single-acting (spring-return) cylinders, clamps and blow circuits; they cannot drive a double-acting cylinder, which needs a 5-port valve from the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.