The AirTAC AirTAC 3V300M-14 3V-F Base (3V300M14F) is a genuine 3V-F manifold base manifold base for 14 stations on one shared air supply. A base is a machined block: it carries no coil and no solenoid, so the valves that sit on it are ordered separately.
Buying a 3/2 valve system starts with deciding how the valves will be mounted, and the 3V300M14F answers that with fourteen stations on one machined manifold. One air supply feeds all fourteen positions, and each fitted valve keeps its own independent 3/2 switching - feed the outlet, or vent it. That layout suits dense panels of single-acting actuators, blow-off points and pilot connections.
The base itself is a genuine AirTAC component with no coil and therefore no voltage, state or power figure of any kind. Valves are ordered separately, so you can fill the fourteen stations with a mixture of states, all five coil voltages and either entry style as the panel requires; the family also offers other station counts. Send an RFQ and we will return the datasheet specifics for the valves you choose.
| Model | AirTAC 3V300M-14 3V-F Base (3V300M14F) |
|---|---|
| Series | 3V-F manifold base |
| Item form | Manifold base (no coil, no solenoid, no initial state) |
| Stations | 14 |
| Port size | Confirm from the datasheet — ask us |
| Thread | PT |
| Operating pressure | Confirm from the datasheet — ask us |
|---|---|
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V-F manifold base | Body. |
|---|---|
| 14F | 14 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A 14-station base turns a crowded backplate of single valves into one ordered block with one feed and one wiring route.
Individual 3/2 stations can drive small air jets for thread guidance or lint cleaning along the machine frame.
Retrofitting an older line often means piloting many larger valves from one point, which a shared manifold does with a single feed.
Buying through this page is deliberately simple: take the 14-station base, then raise an RFQ listing the valves you want on it. For each valve state NC or NO, the port size, one of the five coil voltages, and DIN plug or flying lead - the state decides what the outlet does on power loss, the port must suit the actuator, and the voltage must match the supply because coils are not field-convertible. Our published data for this family stops at the code, so we will confirm pressure, flow and coil power from the datasheet as part of the quote. If the project needs those numbers before you can quote to your own customer, the AirTAC 3V2 and 3V3 bodies publish them; a double-acting cylinder is a job for the 4V series, never a 3/2 valve.
Confirm before you order
Raise the RFQ anyway. We will confirm the pressure, flow and coil-power figures from the AirTAC datasheet and come back with them in the quote. If your project requires published figures before you can quote on, the 3V2 and 3V3 bodies are the documented, fully specified 3-port valves in the range.
The base has no coil, so fourteen valves are ordered separately to fill it. For each one choose NC or NO for the power-loss behaviour, a port size to suit the actuator, a coil voltage to match the panel, and DIN plug or flying-lead entry to match the wiring.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.