AirTAC 4V Series · 5/3-way Solenoid Valve

AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B)

The AirTAC AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with 230E08B ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Exhaust center
  • Port size230E08B
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$51.14 $58.64Save 12% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V230E-08 stroke, mounting and version on one page All 4V230E-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B)

The 4V230E-08B directs compressed air to double-acting cylinders and actuators with a 5/3-way exhaust-center function. When both solenoids are de-energised, the spool moves to the middle position where cylinder ports A and B are connected to exhaust, allowing the cylinder rod to float freely—ideal for applications where the load must be moved manually or by an external force during a machine stop.

This DC24V model draws just 3.0 W and switches in 0.05 s or less. With an effective area of 13.6 mm² (Cv 0.8) and a maximum cycling rate of 3 cycles per second, it suits ~Ø32–50 mm double-acting cylinders. The aluminium-alloy body weighs 360 g, carries an IP65 protection rating, and requires no lubrication when supplied with 40 µm filtered air.

AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B) Technical Specifications

ModelAirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B)
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Exhaust center
Port size230E08B
Exhaust port230E08B
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-230E08BPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B) Is Used

conveyor_belt

Free-Movement Jig Return

On a packaging conveyor, the 4V230E-08B exhausts both sides of a pusher cylinder at the end of the stroke so an operator can slide the jig back by hand without fighting trapped air.

precision_manufacturing

Manual Load-Assist Stations

In an assembly cell, the valve floats a vertical clamp cylinder during part changeover, letting the tooling be repositioned freely before the next automatic cycle locks it in place.

handyman

Two-Hand Safety Circuits

Used in a two-hand start circuit where the exhaust-center state guarantees the press cylinder is vented and cannot drift under residual pressure when the operator releases the buttons.

Is the AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B) the Right Valve?

Choose the 4V230E-08B when your circuit needs the cylinder to go limp at center-off rather than holding position. If you need the piston to lock in place when signals are removed, use the closed-center 4V230C variant instead; if you require both sides pressurised at center, pick the 4V230P. For smaller Ø20–25 mm cylinders the 4V100 series (Cv 0.6) is a better match, while larger Ø63–100 mm bores or faster cycle times call for the 4V300 series (Cv 1.65).

When replacing an existing valve, match five points: body size (4V200), function (5/3 exhaust-center), port and thread (1/4in PT), coil voltage (DC24V), and electrical entry (terminal box). This valve can be mounted singly or ganged on a manifold base, and the manual override lets you test cylinder motion without energising the solenoids.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B) FAQ

Both solenoids de-energise and the spool springs to the center position. In this exhaust-center configuration, ports A and B are vented to atmosphere while the inlet port is blocked. The cylinder rod is free to move, so do not use this valve for load-holding—if the load must stay put, select the closed-center 4V230C or add a pilot-operated check valve at the cylinder ports.

With an effective area of 13.6 mm² (Cv 0.8), it is a good match for double-acting cylinders in the ~Ø32–50 mm range running at typical shop-air pressures of 0.5–0.7 MPa. For smaller Ø20–25 mm cylinders a 4V100-series valve (Cv 0.6) gives finer control, while larger bores or high-speed applications benefit from stepping up to the 4V300 series (Cv 1.65).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V230E-08B Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC24V, terminal entry (4V230E08B)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V230E08B and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.