The AirTAC 4V330E-10E Solenoid Valve, 5/3-way, exhaust center, PT3/8, AC24V, terminal entry (4V330E10E) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT3/8 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-10E is a 5/3-way double-solenoid pneumatic directional valve built on the 4V300 body, configured with an exhaust center spool. When both solenoids are de-energised, the valve moves to its center position where the cylinder ports A and B are connected to exhaust, allowing the attached double-acting actuator to float freely. This makes it the go-to choice for applications where the load must be manually positioned or moved without air resistance when the valve is at rest.
This model is fitted with an AC24V coil drawing 5.0 VA and uses a PT (Rc) tapered thread on its 3/8-inch supply and output ports. With an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and a maximum cycling speed of 3 times per second, it is ideally sized for driving double-acting cylinders in the ~50 to 80 mm bore range. The aluminum alloy body houses a sliding-spool mechanism with a response time of 0.05 seconds or less, and the IP65-rated terminal box entry keeps wiring secure in washdown environments.
| Model | AirTAC 4V330E-10E Solenoid Valve, 5/3-way, exhaust center, PT3/8, AC24V, terminal entry (4V330E10E) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
In assembly jigs where an operator needs to slide a fixture by hand, the exhaust center allows the cylinder to move freely when the valve is idle, eliminating the need to disconnect air lines.
Controls diverter gates on conveyor systems. The float position ensures a gate can be pushed aside by a package if a jam occurs, preventing damage to the actuator or product.
Used on a two-position clamp where the cylinder must hold with pressure in one direction but be completely free for manual part removal after the cycle ends, improving operator safety.
Select the 4V330E-10E when your pneumatic circuit requires a double-acting cylinder to be completely depressurised at rest, such as for manual jogging or setups where back-pressure would be unsafe. The 4V300 body’s Cv 1.25 (catalog figure for the 4V330C-10) is a sweet spot for ~50-80 mm bore cylinders; if you are driving a smaller ~32-40 mm bore, the 4V200 series (Cv 1.0) may offer a more compact and cost-effective solution, while larger ~100-125 mm bores typically benefit from stepping up to the 4V400 body (Cv 2.82).
For a direct replacement, match five key points: the 4V300 body size, the 5/3 exhaust-center function (30E), the 3/8-inch port size, the AC24V coil voltage, and the terminal box electrical entry. If you are building a multi-valve manifold, this valve is compatible with standard 4V300 series bases, allowing you to mix 5/2 and 5/3 functions on a single air supply.
Quick checklist
In the center position (both solenoids off), the valve connects both cylinder ports (A and B) to the exhaust ports, venting all pressure from the actuator. This allows a double-acting cylinder rod to be moved freely by an external force, which is ideal for manual positioning or applications where the load must not be under pressure at rest.
No, this valve alone cannot safely hold a suspended load. The exhaust center function vents all air at rest, so a vertical load would fall. Even in the energized position, a directional valve's spool has internal leakage. For any load-holding or vertical application, you must install a pilot-operated check valve at the cylinder ports or use a dedicated mechanical brake to prevent unintended movement.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.