verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 6HV · Manifold Solenoid Valve

Airtac 6HV Manifold Solenoid Valve 6HV12006C050

Genuine AirTAC manifold solenoid valve, order code 6HV12006C050 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Body and port100 series, 1/8" PT
  • FunctionDouble solenoid (20)
  • Voltage and leadAC110V (C), 0.5 m lead
  • Function5/2 and 5/3-way manifold solenoid valve
  • OperationPilot operated (solenoid)
  • 0500 seriesM5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13)
$43.02 $50.52Save 14%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 6HV body and port, function, voltage and lead on one page All 6HV codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 6HV Manifold Solenoid Valve 6HV12006C050

The 6HV12006C050 orders a 100 series 6HV manifold solenoid valve in the 5/2-way double solenoid build with PT1/8 supply and outlet ports. The 20 function gives the valve a memory: it holds its last switched position when coil power drops, so a momentary control fault does not dump a cylinder mid-stroke. On the 100 series body the 5/2 flow is 8.9 mm2 (Cv 0.52), well above the 3.4 mm2 of the smaller 0500 M5 body, and the valve clips onto a DIN rail manifold with common supply and exhaust so banks can be extended or swapped without disturbing the piping.

In the coil section of the code, C selects AC110V and 050 the 0.5 m lead, sized for a junction box mounted right at the manifold. The plug-in coil draws 1.1 VA, tolerates AC +15% / -10%, and is class F dust-protected; response is 0.05 s or less. AirTAC discontinued the 6HV series in January 2026 and has not named a replacement, so send a quote request with this order code and we will confirm whether this valve can still be supplied.

Airtac 6HV Manifold Solenoid Valve 6HV12006C050 Technical Specifications

Order code6HV12006C050
ProductManifold Solenoid Valve
Body and port100 series, 1/8" PT
FunctionDouble solenoid (20)
Voltage and leadAC110V (C), 0.5 m lead
Function5/2 and 5/3-way manifold solenoid valve
OperationPilot operated (solenoid)
0500 seriesM5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13)
100 seriesM5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47)
FluidAir (filtered by 40 µm element)
Operating pressure0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa
Proof pressure1.2 MPa (175 psi)
Temperature-20 to +70 °C
Max frequency5 cycles/s; 5/3-way 3 cycles/s
BodyAluminum alloy
LubricationNot required
Coil voltagesAC220V, AC110V, DC24V, DC12V
Coil powerAC 1.1 VA · DC 0.7 W
Voltage toleranceAC +15% / -10%, DC ±10%
InsulationClass F, dust-protected
Electrical entryPlug-in connector
Response time0.05 s or less

Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).

How to choose

The 20 in this code picks the double solenoid 5/2 function over the 10 single solenoid (spring return) and the 30C/30E/30P 5/3-way centers. Against 6HV12006C200, this 050 build carries the shorter 0.5 m lead; change the last block to 200 for 2.0 m. For voltage, C is AC110V - A gives AC220V, B DC24V and F DC12V. The 100 series body can also be ordered with M5 ports instead of the 06 PT1/8 build here, and the G or T thread codes switch the port thread from PT to G (BSPP) or NPT.

Applications

packaging

Packaging gripper banks

The double solenoid memory keeps grippers in position through a brief control-power dip, and the DIN rail manifold lets you add or swap stations with common supply and exhaust.

conveyor_belt

Conveyor diverter cylinders

Cv 0.52 flow through PT1/8 ports feeds double-acting diverters and stoppers at up to 0.8 MPa (114 psi) on air filtered to 40 um, with no lubrication needed.

factory

AC110V retrofit panels

The AC110V coil at 1.1 VA drops straight into legacy 110 V control circuits, and the 0.5 m lead reaches a junction box mounted at the manifold.

FAQ

What are the key figures of the 6HV12006C050?

5/2-way double solenoid on the 100 series body with PT1/8 supply and outlet ports. Flow 8.9 mm2 (Cv 0.52) for the 5/2 function. Operating pressure 0.15 to 0.8 MPa (21 to 114 psi) on air filtered to 40 um, proof pressure 1.2 MPa, temperature -20 to +70 C. AC110V coil at 1.1 VA with a 0.5 m lead, class F insulation, 0.05 s or less response.

Can the 6HV12006C050 still be ordered?

AirTAC discontinued the 6HV series in January 2026 and has not named a replacement. Send us a quote request with the order code 6HV12006C050 and we will confirm whether this specific valve can still be supplied.