Genuine AirTAC manifold solenoid valve, order code 6HV120M5C050 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The 6HV120M5C050 is the AC110V version of the 100 series, M5-ported double-solenoid valve in AirTAC's 6HV manifold range, a series AirTAC discontinued in January 2026 without naming a successor. As a 5/2-way valve it flows 8.9 mm2 (Cv 0.52) and reacts in 0.05 s or less, cycling up to 5 times per second, and it mounts with its peers on a DIN rail manifold that shares common supply and exhaust.
The C voltage code brings an AC110V coil rated at 1.1 VA with class F insulation and a generous +15% / -10% voltage tolerance, a good match for plants whose control circuits run on 110 V AC rather than 24 V DC. The 050 code fixes the plug-in lead at 0.5 m for short runs to nearby terminals. The valve runs on air filtered to 40 um at 0.15-0.8 MPa (21-114 psi), -20 to +70 C, without lubrication, and the double solenoid design holds its last switched position whenever coil power is removed.
| Order code | 6HV120M5C050 |
|---|---|
| Product | Manifold Solenoid Valve |
| Body and port | 100 series, M5 |
| Function | Double solenoid (20) |
| Voltage and lead | AC110V (C), 0.5 m lead |
| Function | 5/2 and 5/3-way manifold solenoid valve |
|---|---|
| Operation | Pilot operated (solenoid) |
| 0500 series | M5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13) |
| 100 series | M5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47) |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Max frequency | 5 cycles/s; 5/3-way 3 cycles/s |
| Body | Aluminum alloy |
| Lubrication | Not required |
| Coil voltages | AC220V, AC110V, DC24V, DC12V |
| Coil power | AC 1.1 VA · DC 0.7 W |
| Voltage tolerance | AC +15% / -10%, DC ±10% |
| Insulation | Class F, dust-protected |
| Electrical entry | Plug-in connector |
| Response time | 0.05 s or less |
Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).
Among the 100 series M5 double-solenoid codes, this one differs from 6HV120M5B050 and 6HV120M5B200 only in coil supply: they are DC24V, while 6HV120M5C050 is AC110V with a 0.5 m lead. If your circuit is 24 V DC choose a B code, and for 220 V AC order the A code instead. A spring-return cylinder calls for the single-solenoid 10 code; 5/3-way center behaviors are covered by the 30C, 30E and 30P codes, and 1/8" PT ports by the 06 port code.
The AC110V, 1.1 VA coil connects straight into existing 110 V AC control circuits, so no interposing relay or separate 24 V DC supply is needed to drive this valve.
With the double-solenoid function, a fixture or press cylinder driven by this valve keeps its position through a power interruption, protecting a partially completed assembly.
Cv 0.52 flow and 0.05 s response make this M5 body suitable for several small cylinders per section, all served from one DIN rail manifold with common supply and exhaust.
5/2-way double-solenoid manifold valve, 100 series body, M5 ports, 8.9 mm2 (Cv 0.52), max 5 cycles/s, response 0.05 s or less. Coil AC110V, 1.1 VA, class F, plug-in connector, 0.5 m lead, voltage tolerance AC +15% / -10%. Operating pressure 0.15-0.8 MPa (21-114 psi), proof pressure 1.2 MPa (175 psi), -20 to +70 C, 40 um filtered air, no lubrication.
No. AirTAC lists the 6HV series as discontinued since January 2026 and has not announced a replacement series. To find out whether this exact valve can still be supplied, send a quote request with the order code 6HV120M5C050; we will confirm directly and make no supply promise beforehand.