Genuine AirTAC manifold solenoid valve, order code 6HV130CM5B050 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The 6HV130CM5B050 is the DC24V, short-lead version of the 100 series M5 closed-center valve. Its 30C code means a 5/3-way function whose neutral position blocks supply, outlets and exhaust together, so a load held mid-stroke does not creep while both solenoids are de-energized. Flow on this body is 8.0 mm2 (Cv 0.47) for the 5/3-way, running from 0.2 to 0.8 MPa on air filtered to 40 um, with switching up to 3 cycles/s.
The B in the code selects the DC24V coil, which draws only 0.7 W and tolerates +/-10% supply variation, a natural match for PLC transistor outputs and 24 V control circuits. The 050 lead code keeps the plug-in connector cable at 0.5 m, so the driver or terminal point should sit close to the DIN rail manifold. Coil insulation is class F and response is 0.05 s or less. AirTAC discontinued the 6HV series in January 2026 without naming a replacement; request a quote with the order code so we can confirm whether it can still be supplied.
| Order code | 6HV130CM5B050 |
|---|---|
| Product | Manifold Solenoid Valve |
| Body and port | 100 series, M5 |
| Function | 5/3-way closed center (30C) |
| Voltage and lead | DC24V (B), 0.5 m lead |
| Function | 5/2 and 5/3-way manifold solenoid valve |
|---|---|
| Operation | Pilot operated (solenoid) |
| 0500 series | M5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13) |
| 100 series | M5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47) |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Max frequency | 5 cycles/s; 5/3-way 3 cycles/s |
| Body | Aluminum alloy |
| Lubrication | Not required |
| Coil voltages | AC220V, AC110V, DC24V, DC12V |
| Coil power | AC 1.1 VA · DC 0.7 W |
| Voltage tolerance | AC +15% / -10%, DC ±10% |
| Insulation | Class F, dust-protected |
| Electrical entry | Plug-in connector |
| Response time | 0.05 s or less |
Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).
Compared with the 0500 series M5 valve (6HV030CM5...), this 100 series body doubles the orifice area in the 5/3-way function, 8.0 mm2 (Cv 0.47) against 2.2 mm2 (Cv 0.13), which matters for larger cylinders or faster cycling. Within the same frame, choose 6HV130EM5B050 (exhaust center) or 6HV130PM5B050 (pressure center) if you want controlled release or keep-pressure behavior instead of the full block of the 30C closed center. Over 6HV130CM5B200 this code differs only in lead length: 0.5 m suits a driver card mounted at the manifold, while 200 stretches to 2.0 m. AC110V and DC12V variants are 6HV130CM5C and 6HV130CM5F, and the 1/8 port body is 6HV130C06.
The 0.5 m lead and DC24V plug-in coil let the PLC output sit right beside the DIN rail manifold, at a coil draw of just 0.7 W.
The 30C closed center blocks all five ports in neutral, so a clamped or lifted load keeps its height when both 24 V signals drop.
Cv 0.47 on the 100 series M5 body feeds an index cylinder at up to 3 cycles/s within a 0.2 to 0.8 MPa supply.
5/3-way closed center (30C) manifold solenoid valve, 100 series body with M5 supply and outlets, 5/3-way flow 8.0 mm2 (Cv 0.47), operating pressure 0.2 to 0.8 MPa, max frequency 3 cycles/s, response 0.05 s or less, DC24V coil at 0.7 W (tolerance +/-10%), 0.5 m lead, class F insulation, -20 to +70 C, air filtered to 40 um, no lubrication required.
The 6HV series was discontinued by AirTAC in January 2026 and no replacement series has been named. Submit a quote request with the order code 6HV130CM5B050 and we will check whether this configuration can still be supplied before you plan around it.