Genuine AirTAC manifold solenoid valve, order code 6HV130CM5C200 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
Order 6HV130CM5C200 when the AC110V coil must sit far from the terminal strip: code 200 fits a 2.0 m lead to the plug-in connector. The valve itself is the 100 series 5/3-way manifold unit with M5 ports and a 30C closed center that seals the cylinder ports at neutral, flowing 8.0 mm2 (Cv 0.47) between 0.2 and 0.8 MPa at up to 3 cycles/s.
Like every 6HV valve it clips onto a DIN rail manifold with shared supply and exhaust, vents the pilot exhaust through the R and S ports, and carries a Class F coil that reacts in 0.05 s or less. AirTAC discontinued the 6HV series in January 2026 with no replacement named; ask for a quote with this order code so we can check whether it can still be supplied.
| Order code | 6HV130CM5C200 |
|---|---|
| Product | Manifold Solenoid Valve |
| Body and port | 100 series, M5 |
| Function | 5/3-way closed center (30C) |
| Voltage and lead | AC110V (C), 2.0 m lead |
| Function | 5/2 and 5/3-way manifold solenoid valve |
|---|---|
| Operation | Pilot operated (solenoid) |
| 0500 series | M5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13) |
| 100 series | M5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47) |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Max frequency | 5 cycles/s; 5/3-way 3 cycles/s |
| Body | Aluminum alloy |
| Lubrication | Not required |
| Coil voltages | AC220V, AC110V, DC24V, DC12V |
| Coil power | AC 1.1 VA · DC 0.7 W |
| Voltage tolerance | AC +15% / -10%, DC ±10% |
| Insulation | Class F, dust-protected |
| Electrical entry | Plug-in connector |
| Response time | 0.05 s or less |
Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).
This is the long-lead AC110V member of the closed center M5 group: its neighbour 6HV130CM5C050 carries the same valve on a 0.5 m lead, while 6HV130CM5F050 converts the function to DC12V. Measure the distance from the DIN rail manifold to your terminal strip before choosing 050 versus 200, because the plug-in connector sits where the lead ends. If neutral should dump or pressurize the cylinder ports instead of blocking them, move to the 30E or 30P codes.
The 2.0 m lead lets the DIN rail manifold sit beside the machine while the AC110V plug-in connector reaches a remote control cabinet.
A closed center parks the sealing or pressing cylinder mid-stroke with its ports blocked, useful where the jaw must wait at a set height between cycles.
With M5 ports and 8.0 mm2 flow, the 30C center holds a vertical slide against drift between commanded stops on compact gantries.
This order code combines the 100 series body with M5 ports, the 30C closed center and an AC110V coil on a 2.0 m lead. Flow is 8.0 mm2 (Cv 0.47) for the 5/3-way version, the pressure range is 0.2 to 0.8 MPa with 1.2 MPa proof pressure, the temperature window is -20 to +70 C, maximum frequency is 3 cycles/s, response is 0.05 s or less, and the plug-in coil draws 1.1 VA.