Genuine AirTAC manifold solenoid valve, order code 6HV130EM5C050 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
This AirTAC 6HV code puts a 5/3-way exhaust center valve (30E) on the 100 series M5 body with an AC110V plug-in coil (voltage code C) wired through a 0.5 m lead (lead code 050). With 30E, dropping both solenoid signals vents both cylinder ports through the R and S ports while the supply port stays blocked, so actuators park pressure-free between cycles. The 0.5 m lead suits a manifold clipped to DIN rail right beside the control panel, where a longer pigtail would only add clutter; the class F coil draws 1.1 VA and tolerates AC supply from +15% to -10% of nominal. AirTAC discontinued the 6HV series in January 2026 and has not named a replacement - request a quote with this order code and we will confirm whether it can still be supplied.
In this 5/3-way form the 100 series M5 valve moves 8.0 mm2 (Cv 0.47) of flow through its M5 ports, operates from 0.2 to 0.8 MPa on air filtered by a 40 um element and switches in 0.05 s or less, up to 3 cycles per second. Proof pressure is 1.2 MPa on the aluminum alloy body, lubrication is not required, and the valve is rated from -20 to +70 C.
| Order code | 6HV130EM5C050 |
|---|---|
| Product | Manifold Solenoid Valve |
| Body and port | 100 series, M5 |
| Function | 5/3-way exhaust center (30E) |
| Voltage and lead | AC110V (C), 0.5 m lead |
| Function | 5/2 and 5/3-way manifold solenoid valve |
|---|---|
| Operation | Pilot operated (solenoid) |
| 0500 series | M5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13) |
| 100 series | M5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47) |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Max frequency | 5 cycles/s; 5/3-way 3 cycles/s |
| Body | Aluminum alloy |
| Lubrication | Not required |
| Coil voltages | AC220V, AC110V, DC24V, DC12V |
| Coil power | AC 1.1 VA · DC 0.7 W |
| Voltage tolerance | AC +15% / -10%, DC ±10% |
| Insulation | Class F, dust-protected |
| Electrical entry | Plug-in connector |
| Response time | 0.05 s or less |
Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).
This code shares its body and function with 6HV130EM5B200 (DC24V coil) and 6HV130EM5C200 (AC110V with a 2.0 m lead); take the 050 lead only when the short length matches your wiring layout. Within the 5/3 family, 30C blocks the cylinder ports on de-energization and 30P pressurizes them, while 30E exhausts them as this code does. If M5 is too small for your circuit, port code 06 selects the PT1/8 version of the same 100 series body, and codes 10 or 20 change the valve to a 5/2 function.
Mount the DIN rail manifold next to the terminal strip and connect the AC110V coil on its short 0.5 m lead without excess cable to route.
Use the exhaust center behavior to vent clamps or slides when the machine stops, so tooling can be adjusted by hand without trapped air.
Exhaust grippers and pushers through R and S during format changes, then restore supply automatically when the 30E valve re-energizes.
100 series body with M5 supply and outlets; 5/3-way exhaust center function; flow 8.0 mm2 (Cv 0.47); operating pressure 0.2 to 0.8 MPa, proof pressure 1.2 MPa; AC110V coil at 1.1 VA with a +15% / -10% tolerance; 0.5 m lead; response 0.05 s or less; max 3 cycles/s; -20 to +70 C; air filtered to 40 um; no lubrication required.
No. AirTAC discontinued the 6HV series in January 2026 and has not named a replacement. Request a quote with this order code and we will confirm whether the valve can still be supplied.