verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 6HV · Manifold Solenoid Valve

Airtac 6HV Manifold Solenoid Valve 6HV130P06A200

Genuine AirTAC manifold solenoid valve, order code 6HV130P06A200 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Body and port100 series, 1/8" PT
  • Function5/3-way pressure center (30P)
  • Voltage and leadAC220V (A), 2.0 m lead
  • Function5/2 and 5/3-way manifold solenoid valve
  • OperationPilot operated (solenoid)
  • 0500 seriesM5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13)
$52.33 $59.83Save 12%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 6HV body and port, function, voltage and lead on one page All 6HV codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 6HV Manifold Solenoid Valve 6HV130P06A200

This 6HV130P06A200 is the 100 series 5/3-way code with a pressure center (30P) on 1/8 in PT ports, wired with an AC220V coil (code A) on a 2.0 m lead (code 200). In the neutral position the pressure center keeps both cylinder ports pressurized instead of dumping or blocking them, which is the position to pick when a load must stay held while the solenoid is off. On the 100 series body the 5/3-way version flows 8.0 mm2 (Cv 0.47), switches up to 3 cycles/s and runs from 0.2 to 0.8 MPa on air filtered to 40 um.

The AC220V coil draws 1.1 VA, is Class F insulated in a dust-protected plug-in connector, and its 2.0 m lead lets you place the connection point away from the DIN rail manifold. Note that AirTAC discontinued the 6HV series in January 2026 without naming a replacement, so request a quote with this order code and we will confirm whether it can still be supplied.

Airtac 6HV Manifold Solenoid Valve 6HV130P06A200 Technical Specifications

Order code6HV130P06A200
ProductManifold Solenoid Valve
Body and port100 series, 1/8" PT
Function5/3-way pressure center (30P)
Voltage and leadAC220V (A), 2.0 m lead
Function5/2 and 5/3-way manifold solenoid valve
OperationPilot operated (solenoid)
0500 seriesM5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13)
100 seriesM5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47)
FluidAir (filtered by 40 µm element)
Operating pressure0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa
Proof pressure1.2 MPa (175 psi)
Temperature-20 to +70 °C
Max frequency5 cycles/s; 5/3-way 3 cycles/s
BodyAluminum alloy
LubricationNot required
Coil voltagesAC220V, AC110V, DC24V, DC12V
Coil powerAC 1.1 VA · DC 0.7 W
Voltage toleranceAC +15% / -10%, DC ±10%
InsulationClass F, dust-protected
Electrical entryPlug-in connector
Response time0.05 s or less

Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).

How to choose

Pick 30P over its 5/3 siblings 30C (closed center) and 30E (exhaust center) when both cylinder ports must stay pressurized in neutral, and over the 5/2 codes 10 (single solenoid) and 20 (double solenoid) when you need a true mid position. This code fixes AC220V with a 2.0 m lead; the shorter lead lives on 6HV130P06A050, and DC24V, AC110V and DC12V versions are the B, C and F codes such as 6HV130P06B200. For the smaller M5-port 0500 series body, use the 05 series code instead.

Applications

valve

Clamping circuits that hold pressure

The 30P center keeps both ports of a clamping cylinder pressurized when the coil is off, so a fixture does not lose its grip between machine cycles.

forklift

Pallet stopper with mid-stroke pause

A stopper cylinder can be parked part-way out with pressure on both sides of the piston and released again the moment the AC220V coil is energized.

electrical_services

Coil wired away from the manifold

The 2.0 m lead reaches a control cabinet that is not next to the DIN rail manifold, with the plug-in Class F connector at the coil end.

FAQ

What are the key figures of the 6HV130P06A200?

100 series manifold solenoid valve, 5/3-way with pressure center (30P), 1/8 in PT supply and outlets, flow 8.0 mm2 (Cv 0.47), operating pressure 0.2 to 0.8 MPa, max 3 cycles/s, response 0.05 s or less, AC220V coil at 1.1 VA, Class F insulation, 2.0 m lead, -20 to +70 C.

The series is discontinued - can I still order this valve?

AirTAC stopped selling the 6HV series in January 2026 and has not named a replacement. Send us a request for quote with the order code 6HV130P06A200 and we will confirm whether this exact valve can still be supplied.