Genuine AirTAC manifold solenoid valve, order code 6HV130P06C200 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
In the 6HV ordering code, 6HV130P06C200 identifies the 100-series body, 1/8 PT ports, the 30P pressure center and an AC110V coil on a 2.0 m lead. With the center pressurized in neutral, a stopped cylinder keeps pressure on both sides, and the 8.0 mm2 (Cv 0.47) 5/3 flow supports up to 3 cycles/s between 0.2 and 0.8 MPa.
The long 2.0 m lead is the point of this code: it reaches a control cabinet mounted away from the DIN-rail manifold, while the pilot exhaust still vents through the common R and S ports and the plug-in class F coil responds in 0.05 s or less. The 6HV series was discontinued in January 2026 with no replacement named, so send this order code for a quote and we will confirm whether it can still be supplied.
| Order code | 6HV130P06C200 |
|---|---|
| Product | Manifold Solenoid Valve |
| Body and port | 100 series, 1/8" PT |
| Function | 5/3-way pressure center (30P) |
| Voltage and lead | AC110V (C), 2.0 m lead |
| Function | 5/2 and 5/3-way manifold solenoid valve |
|---|---|
| Operation | Pilot operated (solenoid) |
| 0500 series | M5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13) |
| 100 series | M5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47) |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Max frequency | 5 cycles/s; 5/3-way 3 cycles/s |
| Body | Aluminum alloy |
| Lubrication | Not required |
| Coil voltages | AC220V, AC110V, DC24V, DC12V |
| Coil power | AC 1.1 VA · DC 0.7 W |
| Voltage tolerance | AC +15% / -10%, DC ±10% |
| Insulation | Class F, dust-protected |
| Electrical entry | Plug-in connector |
| Response time | 0.05 s or less |
Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).
Compared with 6HV130C06C200 (closed center) and 6HV130E06C200 (exhaust center), this 30P code is the one to order when a held load must stay pressurized rather than vented or locked. If your coil supply is not AC110V, use A for AC220V, B for DC24V or F for DC12V at the same position in the code, and 050 instead of 200 for the short 0.5 m lead. The 0500-series M5 body (code 05) offers only 2.2 mm2 (Cv 0.13) in the 5/3 version.
The 2.0 m lead reaches a control cabinet mounted away from the DIN-rail manifold, so the AC110V plug-in connector can be driven without rerouting the machine-side coil wiring.
In a palletizer, a layer clamp held by the 30P pressure center keeps both cylinder ports pressurized in neutral, so the load does not sag between cycles on the 1/8 PT 100-series body.
Clipped to a shared DIN-rail manifold with common supply and exhaust, the valve can be swapped station to station; the 2.0 m lead keeps each station's coil wiring independent of manifold position.
5/3-way pressure center (30P) on the 100-series body, 1/8 PT ports, 8.0 mm2 flow (Cv 0.47), 0.2 to 0.8 MPa, max 3 cycles/s, response 0.05 s or less, AC110V coil drawing 1.1 VA on a 2.0 m lead, class F plug-in coil, -20 to +70 C, proof pressure 1.2 MPa, air filtered to 40 um.
AirTAC discontinued the 6HV series in January 2026 and has not named a replacement. We do not promise availability here; request a quote with the order code 6HV130P06C200 and we will confirm whether this valve can still be supplied.