verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 6TV · 3/2-Way Solenoid Valve

Airtac 6TV Solenoid Valve 6TV11006NCF050

Genuine AirTAC 3/2-way solenoid valve, order code 6TV11006NCF050 from the 6TV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Body and port100 series, 1/8" PT
  • FunctionSingle solenoid, normally closed (10, NC)
  • Voltage and leadDC12V (F), 0.5 m lead
  • Function3/2-way solenoid valve
  • OperationPilot operated (solenoid)
  • 0500 seriesM5 supply, outlets and exhausts · 3.4 mm² (Cv 0.2)
$27.88 $35.38Save 21%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 6TV body and port, function, voltage and lead on one page All 6TV codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 6TV Solenoid Valve 6TV11006NCF050

The 6TV11006NCF050 decodes as a 100 series 6TV valve with PT1/8 supply, outlet and exhaust, a single (10) solenoid that is normally closed, and a DC12V coil (voltage code F) on a 0.5 m lead. AirTAC discontinued the 6TV series in January 2026 and has not named a replacement, so send us this order code for a quote and we will confirm whether it can still be supplied.

On the 100 series body the valve flows 8.9 mm2 (Cv 0.52) and weighs 52 g. The pilot-operated design runs from 0.15 to 0.8 MPa (21 to 114 psi) on air filtered by a 40 um element, responds in 0.05 s or less, and the class F DC coil draws 0.7 W within a +/-10% voltage tolerance.

Airtac 6TV Solenoid Valve 6TV11006NCF050 Technical Specifications

Order code6TV11006NCF050
Product3/2-Way Solenoid Valve
Body and port100 series, 1/8" PT
FunctionSingle solenoid, normally closed (10, NC)
Voltage and leadDC12V (F), 0.5 m lead
Function3/2-way solenoid valve
OperationPilot operated (solenoid)
0500 seriesM5 supply, outlets and exhausts · 3.4 mm² (Cv 0.2)
100 seriesM5 or PT1/8 supply, outlets and exhausts · 8.9 mm² (Cv 0.52)
200 seriesPT1/8 or PT1/4 supply and outlets, PT1/8 exhausts · 15.4 mm² (Cv 0.91)
300 seriesPT3/8 supply and outlets, PT1/4 exhausts · 38.4 mm² (Cv 2.26)
Weight6TV0510 28 g · 6TV0520 43 g · 6TV110 52 g · 6TV120 67 g · 6TV210 90 g · 6TV220 105 g · 6TV310 180 g · 6TV320 215 g
FluidAir (filtered by 40 µm element)
Operating pressure0.15 – 0.8 MPa (21 – 114 psi)
Proof pressure1.2 MPa (175 psi)
Temperature-20 to +70 °C
Max frequency5 cycles/s
BodyAluminum alloy
LubricationNot required
Coil voltagesAC220V, AC110V, DC24V, DC12V
Coil powerAC 1.1 VA · DC 0.7 W
Voltage toleranceAC +15% / -10%, DC ±10%
InsulationClass F, dust-protected
Electrical entryPlug-in connector
Response time0.05 s or less

Source: AirTAC 6TV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6TV series as discontinued (January 2026).

How to choose

Pick this code over 6TV11006NCF200 when the coil sits close to the valve and the 0.5 m lead is enough. Against 6TV21006NCF050 on the 200 series it trades the larger 15.4 mm2 / Cv 0.91 flow for the smaller 100 series footprint on the same 1/8 port; against 6TV11006NOA050 it closes instead of opening with no signal. If DC12V is not your supply, voltage code B in the same body is DC24V.

Applications

precision_manufacturing

Energize-to-actuate cylinders

The normally closed function shuts the PT1/8 outlet the moment power is lost, so a small cylinder only strokes while the DC12V coil is driven.

cable

Short-harness DC wiring

The 0.5 m lead suits panels where the driver sits next to the valve, with DC12V held within the +/-10% tolerance and 0.7 W coil draw.

valve

Pilot and signal circuits

Cv 0.52 (8.9 mm2) flow covers air signals and small actuators at up to 5 cycles/s with a 0.05 s or faster response.

FAQ

What are the key figures of the 6TV11006NCF050?

100 series body with PT1/8 ports; 3/2-way single solenoid, normally closed; 8.9 mm2 (Cv 0.52); 0.15 to 0.8 MPa (21 to 114 psi); DC12V coil at 0.7 W, class F, +/-10% tolerance; 0.5 m lead; response 0.05 s or less; max 5 cycles/s; 52 g; -20 to +70 C on 40 um filtered air.

Can AirTAC still supply this valve?

The 6TV series was discontinued by AirTAC in January 2026 and no replacement series has been named. Request a quote with the order code 6TV11006NCF050 and we will confirm whether this valve can still be supplied.