Genuine AirTAC 3/2-way solenoid valve, order code 6TV11006NOC200 from the 6TV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The 6TV11006NOC200 pairs the normally open (NO) single-solenoid function with a 2.0 m coil lead, double the 0.5 m of the 050 code, so the plug-in AC110V coil can be wired from a control cabinet or junction box that sits well away from the valve. The valve itself is the 100 series body: PT1/8 supply, outlet and exhaust ports, 8.9 mm2 effective area (Cv 0.52) and 52 g of weight.
Pilot operated and fed with air filtered to 40 um, it works from 0.15 to 0.8 MPa (21 to 114 psi), tolerates a 1.2 MPa proof pressure, spans -20 to +70 C and needs no lubrication. Switching takes 0.05 s or less at up to 5 cycles/s, and the 1.1 VA class F coil accepts the plug-in connector with its terminal facing sideways or up. AirTAC discontinued the 6TV series in January 2026 and has not named a replacement, so request a quote with this order code to confirm whether it can still be supplied.
| Order code | 6TV11006NOC200 |
|---|---|
| Product | 3/2-Way Solenoid Valve |
| Body and port | 100 series, 1/8" PT |
| Function | Single solenoid, normally open (10, NO) |
| Voltage and lead | AC110V (C), 2.0 m lead |
| Function | 3/2-way solenoid valve |
|---|---|
| Operation | Pilot operated (solenoid) |
| 0500 series | M5 supply, outlets and exhausts · 3.4 mm² (Cv 0.2) |
| 100 series | M5 or PT1/8 supply, outlets and exhausts · 8.9 mm² (Cv 0.52) |
| 200 series | PT1/8 or PT1/4 supply and outlets, PT1/8 exhausts · 15.4 mm² (Cv 0.91) |
| 300 series | PT3/8 supply and outlets, PT1/4 exhausts · 38.4 mm² (Cv 2.26) |
| Weight | 6TV0510 28 g · 6TV0520 43 g · 6TV110 52 g · 6TV120 67 g · 6TV210 90 g · 6TV220 105 g · 6TV310 180 g · 6TV320 215 g |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15 – 0.8 MPa (21 – 114 psi) |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Max frequency | 5 cycles/s |
| Body | Aluminum alloy |
| Lubrication | Not required |
| Coil voltages | AC220V, AC110V, DC24V, DC12V |
| Coil power | AC 1.1 VA · DC 0.7 W |
| Voltage tolerance | AC +15% / -10%, DC ±10% |
| Insulation | Class F, dust-protected |
| Electrical entry | Plug-in connector |
| Response time | 0.05 s or less |
Source: AirTAC 6TV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6TV series as discontinued (January 2026).
This code and the 6TV11006NOC050 are functionally identical normally open valves on the same PT1/8 100 series body; the only difference in the order code is the lead, 200 for 2.0 m versus 050 for 0.5 m. Choose the 200 lead when the coil drop has to reach a distant enclosure, and the 050 when wiring is short. If your circuit must seal rather than pass in the idle state, look at the normally closed 6TV11006NCC200, and for position-holding logic move to a double-solenoid 20 version.
Where the PT1/8 valve sits low on the machine frame and the electrical enclosure is meters away, the 2.0 m coil lead on the AC110V plug-in connector covers the run without splicing.
Replacing a valve in an existing AC110V machine where the original coil drop was sized at 2 m keeps the cabinet wiring untouched, since the 200 code lead length matches the run.
In circuits that must keep passing air when de-energized, the normally open function holds flow through the Cv 0.52 orifice until the single solenoid is switched to cut it.
3/2-way single solenoid valve, normally open (NO). 100 series body, PT1/8 supply, outlet and exhaust, 8.9 mm2 (Cv 0.52), 52 g. Operating pressure 0.15 to 0.8 MPa (21 to 114 psi), proof 1.2 MPa. -20 to +70 C, response 0.05 s or less, max 5 cycles/s. AC110V coil, 1.1 VA, class F, plug-in entry with a 2.0 m lead (order code 200). Air filtered to 40 um, no lubrication required.
No supply promise can be made: AirTAC lists the 6TV series as discontinued as of January 2026 and has not named a replacement. Request a quote using the order code 6TV11006NOC200 and we will confirm whether this specific valve can still be supplied.